EUROSTER 11E USER MANUAL

3

way.

Normal operation:

 <-> 

supply temperature between 35ºC and 90ºC

Overheating:

 <-> 

supply temperature > 90ºC

Furnace put out:

supply temperature < 35ºC

6

TURNING THE CONTROLLER ON

Turn the controller mains switch (4 in section 3) into the “I” position.

Device firmware version No. and compilation date are sequentially displayed for 2 s.

“AS” letters are blinking on the display while the ANTY STOP function turns on the 
pump.

State of the system is shown on the display.

If the controller is being turned on for the first time: select the desired mode of 

operation (see section 7 below) and set the desired controller presets (see section 8 
below).

7

MODE OF OPERATION AND FACTORY (DEFAULT) PRESETS 

The

 EUROSTER E11E

 controller may be operated in two modes: it may control CH system 

pump or UHW system pump. In the former mode the CH system pump is engaged if sensor 

temperature has exceeded the preset limit. In the latter mode the UHW system pump is kept 
running until sensor temperature reaches the preset value. 
Restore one of the factory default presets to change the mode:

Set 1 

has been complied for layouts in which CH system pump is controlled 

Set 2

 has been complied for layouts in which UHW pump is controlled.

Proceed as follows to restore factory presets (e.g. in order to change the controller operational 

mode):

Press the knob and while holding it depressed turn the controller off and on. 

Fd

” (factory defaults) is displayed.

Release the knob. Digit 0 is displayed.

Select the desired set of defaults (1 or 2) and accept the selection.

Check and correct the presets if needed.

8

CONTROLLER PRESETS

Shortly after power supply of the controller is turned on, current state of the system is shown 
on the display. Turn the knob to the right to enter the preset browse/edit mode. General 

procedure to edit a preset:

1. Turn the knob to select the desired preset (parameter). The controller displays current 

value of the selected parameter (top) and its number (bottom). 

2. Press the knob. The displayed parameter value starts to blink.
3. Set the desired new value and press the knob to accept it

or 

Wait 10 seconds until the displayed parameter value stops blinking in order to abort the 
edit procedure (to leave the current value intact)  

Configuration windows are numbered to facilitate manipulations. User may edit the following 

Содержание 11E

Страница 1: ...gainst seizing Once the heating season is over every 14 days the function automatically turns ON the pumps for 30 seconds To that end the controller must be left powered up 3 VISIBLE CONTROLLER ELEMEN...

Страница 2: ...power supply cable into a 230V 50Hz mains socket equipped with a grounding pin The controller must not be installed in a place where the ambient temperature may exceed 40 C 5 CONTROLLER DISPLAY Eleme...

Страница 3: ...s to change the mode Set 1 has been complied for layouts in which CH system pump is controlled Set 2 has been complied for layouts in which UHW pump is controlled Proceed as follows to restore factory...

Страница 4: ...0 80 80 C Pump hysteresis 4 4 2 2 10 10 C Temperature sensor correction 0 0 5 5 5 5 C Pump manual operation test as calculated by the controller as calculated by the controller 0 OFF 0 OFF 1 ON 1 ON 9...

Страница 5: ...d a odwo ania Check pump connection d Controller knob operates erratically Pulse generator failure Have the controller serviced 12 COMPATIBILITY WITH STANDARDS CERTIFICATES The EUROSTER 11E controller...

Страница 6: ...operate the system is shown Central heating pump control mode 1 EUROSTER 11E controller 2 CH boiler 3 Heat source temperature sensor 4 CH pump 5 Radiator heat load Utility hot water pump control mode...

Страница 7: ...arranty terms 1 Warranty is valid for 24 months from the controller sale date 2 Warranty is valid exclusively on the territory of Poland 3 Claimed controller together with this warranty certificate mu...

Отзывы: