202206-609-ENG
User manual - JETPRO 80 & 100
P13
4. USE OF THE MACHINE (continued)
4.4. ERROR CODES
The different error codes show up on the display (A1).
CODES
DEFINITION
TO DO
No display.
Plug the machine into the power supply, assure the power supply is
230 V, verify the fuse in the electric box.
Emergency stop is
on.
Unlock the emergency stop button (AU).
Machine is in the
stop mode.
Switch the machine on by pressing on the button (1).
Default control
engine.
Set the machine to OFF for one minute and then switch it back on.
5. DEFECTS AND REMEDIES
Defect
Remedy
The display does not light up (no display).
•
Verify the power supply.
The display indicates an error code.
• See table above.
The pump is blocked.
• After a prolonged standstill, the pump might be
blocked.
See procedure 4.1. page 10.
The pressure is insufficient.
• Verify that the setting is strong enough.
•
Verify that the nozzle is not too big or worn out.
•
Verify the wear of the pump.
If the problem persists or if in doubt on the good running of the machine, do not try to repair
it by yourself or to dismantle it.
Contact an authorized After-Sale Service or our hotline : +33 4 42 29 08 96.
In case of an unknown defect or a doubt on the good running of the machine, do not try to
repair it by yourself or to dismantle it.
Contact an authorized After-Sale Service or our hotline : +33 4 42 29 08 96.