background image

3

7         0

SET-UP Test Option: 5 options:

7.1

Sub-menu 

USER SET-UP: Permits the master user to change it's own user 
name and user code. The master user can change the names, codes 
and options of any user on any suite. The service user can change 
it's own name and code, and the name and code of the other users 
(except the master user) on any suite. The other 4 users on the 
Concierge Panel are allowed to change their own names, codes and
options but only the name of a user lower in status and may not 
alter the set-up of any higher status user, e.g. the master.

7.2

Sub-menu

SYSTEM SET-UP: 2 options

7.2.1

SET ZONES

7.2.2

SET VARIABLES

7.3

Sub-menu

SERIAL SET-UP: Allows set-up of the serial channel 1 & serial 
channel 2 parameters:

7.3.1

Baud Rate      

7.3.2

Data Bits

7.3.3

Parity

7.3.4

Filter Byte 1

7.3.5

Filter Byte 2

7.3.6

System ID

7.3.7

Access Control

7.4

Sub-menu

UP/DOWNLOAD DATA: 2 options:

7.4.1

UPLOAD DATA TO PC: This allows the user to upload 
data from the panel to a PC.

7.4.2

DOWNLOAD DATA FROM PC: This allows the user to 
download data from a PC to the panel.

N.B. Once selected, this routine surrenders control to an external master program and normal
panel operation is suspended until the upload/download has completed.

7.5

Sub-menu

SUITE MONTIOR: Checks for a suite on-line.

Содержание SUITEPLEX 3850

Страница 1: ...CARBOROUGH ONTARIO CANADA M1B 3L6 TEL 416 754 4313 FAX 416 754 8992 E MAIL admin intramerica biz INSTALLATION AND OPERATION MANUAL FOR SUITEPLEX MODEL 3850 CONCIERGE CONTROL PANEL C COPYRIGHT EUROPLEX...

Страница 2: ...TENTS HOW TO INITIALIZE THE SUITES SYSTEM OPTIONS NOTE CONCIERGE PANEL USER OPTIONS CONCIERGE PANEL SINGLE KEY FUNCTIONS SUITE PANEL USER OPTIONS SUITE PANEL SINGLE KEY FUNCTIONS FUNCTION This documen...

Страница 3: ...he NO key The panel will show HIGH SPEED COMMS Press the YES key The panel will show OVERWRITE SUITE IDS If the panel has not been cold start zapped thus removing the IDS from the panel press the YES...

Страница 4: ...Y OPTION 1 DISARM DISARM Functions 3 options 1 1 Disarm Concierge to accept alerts or Disarm the Concierge Panel 1 2 Disarm Suite to accept alerts or Disarm specified suites 1 3 Acknowledge Alarms to...

Страница 5: ...e g the master 7 2 Sub menu SYSTEM SET UP 2 options 7 2 1 SET ZONES 7 2 2 SET VARIABLES 7 3 Sub menu SERIAL SET UP Allows set up of the serial channel 1 serial channel 2 parameters 7 3 1 Baud Rate 7...

Страница 6: ...erts the user that a battery test has been done and causes an alarm if the battery is faulty 12 5 SPARE MODE Literal available for mode command 13 6 SPARE MODE Literal available for mode command 14 7...

Страница 7: ...g the user to enter the suite number and then executing the Evening Arm literal on that suite The QUIT key exits 3 Remote Sleep Arm This routine allows the user to Sleep Arm any on line suite by promp...

Страница 8: ...when finished The revised literal will now be stored in memory 7 Set up Test Option Pressing the NEXT key or the PREV key moves forwards or backwards respectively through the 5 options available and t...

Страница 9: ...key to exit the option 7 2 2 Set Variables The user is prompted with the variable and it s default value The new value should be entered To select the next variable the NEXT key should be pressed Pre...

Страница 10: ...sing the YES ENTER or QUIT key has the effect described in 7 3 1 Any integer less than 256 will be accepted 7 4 Up Download Data 7 4 1 Upload Data i Once selected the panel will suspend normal operati...

Страница 11: ...selects the option The QUIT key exits the routine 9 1 View Log This causes all events logged by the Concierge panel and each Suite panel to be displayed on the Concierge Panel displayed in reverse ch...

Страница 12: ...FROM SUITE NO When this is entered the next prompt is TO SUITE NO When this has been entered check is carried out to ensure that the maintenance code has been set 10 1 and if that is the case then the...

Страница 13: ...d as in 14 1 By accepting the default values the message which was sent to all suites will be cleared otherwise the message will be cleared from the displays of the suites in the specified range The Q...

Страница 14: ...mes codes and options of any user on the suite The service user can change it s own name and code and the name and the code of other suite users except user 1 The other suite users are allowed to chan...

Страница 15: ...d read ii Otherwise press the ENTER key and go to iii ii The previous name which may be the default name is displayed in the edit mode This name may be changed by first deleting it using the SHIFT key...

Страница 16: ...NGLE KEY FUNCTIONS KEY OPERATION FIRE Causes alarm and sets relay on suite PANIC Alarm and relay EMERG Alarm relay and buzzer These keys have to be depressed for 3 seconds or pressed 3 times in succes...

Отзывы: