APPENDIX ONE

Troubleshooting

 

Burner 

lights when 

pilot only 

should light

 

Yes 

Pilot 

holds 

flame?

 

No 

1.

Verify transmitter is not powered on or in thermostat mode calling

 

for heat.  Display should say OFF next to thermometer  image on

 

display for thermo off.

2.

Ensure all electrical connections are secure based on the wiring

 

diagram

3.

Verify proper voltage at the main valve connection ( EV2 green).

 

-

If voltage is present replace IFC board

-

If voltage is not present replace gas valve (solenoid not

 

closing)

1.

Verify pilot flame makes full contact with flame sensor

-

Verify gas pressure on full capacity

-

Verify turbulence is not pushing flame off flame sensor

2.

Clean the flame sensor and inspect wiring for damage

3.

Verify pilot assembly is properly grounded and pilot hood is

 

brushed clean of debris and securely pressed down.

4.

Replace flame sensor

5.

Check voltage at pilot valve connection (EV1 orange) 

-

If no voltage present when calling for pilot, replace IFC

board

 

-

If voltage is present, replace gas valve (valve not

opening)

Main 

burner 

ignites?

 

No 

1.

Verify the receiver switch is in ON position

-

If 

equipped,

 verify 

receiver switch

 is powered ON

and thermostat is OFF. 

2.

Verify electrical connections are properly connected according to

 

the wiring diagram and replace any damaged harnesses

3.

Verify the pilot flame is properly directed to ignite the burner

4.

Verify piezo is not sparking if so, go back to Piezo Still Sparking

5.

Verify proper components are installed for type of gas used

6.

Check continuity of the main burner coil.  

7.

Check for voltage at the main burner connection (EV2 green) 

-

If voltage is present replace gas valve (not opening)

-

If no voltage is present replace IFC board

No 

Yes 

Main burn-­

er remains 

on

 

No 

1.

Verify the receiver switch is in ON position

-

If 

equipped, verify that the receiver switch is on

2. Verify that the knockouts on the back or side of the unit have been    

   

sealed to prevent air infiltration from the wall.

3.

Verify electrical components are properly connected according to

 

the wiring diagram and replace any damaged harnesses

4.

Verify pilot flame makes contact with flame sensor.  Clean flame

 

sensor of any debris or silicone film.

5.

Verify gas pressure on full capacity is according to manual

6.

Check for voltage at the main burner connection (EV2 green) 

-

If voltage is present when drops out, replace gas valve

-

If no voltage, replace IFC board

Yes 

Yes 

Содержание H Series

Страница 1: ...xactly a fire or explosion may result causing property damage personal injury or loss of life This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilating air must be provided Refer to page 6 INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be insta...

Страница 2: ......

Страница 3: ...llation Planning 11 Rough Installation 16 Electric Installation 17 Gas Installation 19 Trim and Finish 20 Operating the Fireplace 22 Maintenance 24 Parts List 25 Warranty 26 Troubleshooting Appendix One Connecting a Home Automation System Appendix Two Installing The Air Shutter Kit Appendix Three Optional Fireplace Screen Appendix Four Installing the Heat Deflector Appendix Five ...

Страница 4: ... heater 4 Do not place clothing or other flammable material on or near the heater Any change to this heater or its controls can be dangerous Improper installation or use of the heater can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Do not use a blower ins...

Страница 5: ...cal codes with the National Fuel Gas Code ANSI Z223 l NFPA54 11 This unit was tested and listed to ANSI Z21 11 2 2016 Gas fired Room Heaters Volume II Unvented Room Heaters by OMNI Test Laboratories This unit is intended for indoor use only 12 This appliance is approved for installation in the Commonwealth of Massachusetts The Board of State Examiners of Plumbers and Gas Fitters has issued approva...

Страница 6: ... in period will be slight and will disappear with continued use 21 Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet If your installation is at an elevation greater than these consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations 22 The appliance and its appliance mai...

Страница 7: ... 1 000 BTU per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE a walls and ceilings exposed to the outside atmosphere have a ...

Страница 8: ...ion of unconfined space that is al lowed in your space Maximum BTU Hr x 1000 Example A Consider two connecting rooms with an open area between with the following dimensions L1 151 2 ft L2 12 ft W 12 ft H 8 ft x 1000 52 800 BTU Hr Example B If there were a door between the two rooms the calculation would be based only on the room with the heater x 1000 29 760 BTU Hr Will my space support a H Series...

Страница 9: ...ormation is for reference only Please consult the Installation Manual for all details prior to making any design decisions Conversions from millimeters are rounded to the nearest fraction A DWG file is available at www europeanhome com www EuropeanHome com HVF See Through 04 17 2020 EuropeanHome com ...

Страница 10: ...r to reapplication manufactured by EUROPEAN HOME a division of Europa Ja Inc 30 Log Bridge Road Building 300 Suite 303 Middleton MA 01949 www europeanhome com Max Input BTU hr 37 500 Min Input BTU hr 25 000 Max Supply Pressure 7 inches w c Min Supply Pressure 4 inches w c Max Manifold Pressure 3 5 inch w c Report Number 0284GF007S DO NOT INSTALL HEATER UNTIL ALL NECESSARY PROVISIONS ARE MADE FOR C...

Страница 11: ...ombustible Standard and Type X drywall are both combustible NON COMBUSTIBLE MATERIALS A given material is said to be non combustible when it cannot catch fire and burn For example materials made entirely orincombinations of stone brick concrete tile steel plasterorglassareconsiderednon combustible See the chart below for a list of materials which as of this writing are reported by their manufactur...

Страница 12: ...ace This fireplace has been designed to provide you with safe trouble free operation Please read this manual thoroughly before beginning the installation of your fireplace It has information which is important for safe installation and operation Please inspect your shipment for completeness and any damage Contact your retailer if any damage is found Do not install your fireplace with any damaged o...

Страница 13: ...be placed on a raised platform This appliance is a HEATING appliance and it becomes hot in operation DO NOT PLACE any object furniture draperies or other item LESS THAN 36 inches from the front of the fireplace The clearance dimensions shown throughout this manual MUST be maintained for safety as well as servicing and maintenance Possible Fireplace Locations 6 min A 36 90cm 36 90cm 36 90cm 36 90cm...

Страница 14: ...SING CLEARANCES Mantel Ceiling and Enclosure Clearances side view not to scale NON COMBUSTIBLE Wall Face Fireplace Opening Top Line of Fireplace Opening Room Ceiling Combustible Wall Face 231 8 Fireplace Opening minimum minimum 11 36 263 4 231 8 0 12 Combustible Enclosing Ceiling Combustible Mantel 4 36 11 4 0 12 ...

Страница 15: ...lled on a metal or wood panel extending the full width and depth of the fireplace cabinet When enclosing your fireplace the use of non combustible building materials is required Please read and understand the COMBUSTIBLE MATERIALS and NON COMBUSTIBLE MATERIALS section MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS HVF 42 ST HVF 60 ST HVF 72 ST Clearance to Top Standoffs 0 0 Clearance to Side Standoff...

Страница 16: ...t least one of the walls must be framed with jack studs which are fastened to the king studs after the fireplace is set into place 2 Place the fireplace into the rough opening and fasten the jack studs to the king studs Framing material can touch the standoffs at the sides of the cabinet but do not place anything between the framing and the standoffs 3 Make sure the fireplace is both level and squ...

Страница 17: ...to a 120V AC branch circuit according to all applicable codes The neutral line and ground wires to the receptacle are available at the lower left corner of the fireplace cabinet This circuit must be wired such that the AC power to the H Series Vent Free Gas Fireplace may be turned off by an accessible single pole switch This circuit need not be dedicated to the H Series Vent Free Gas Fireplace unl...

Страница 18: ...TRIC INSTALLATION 18 H Series Vent Free Fireplace Rev 12042020 EuropeanHome com Electrical Connection Diagram IFC Control Module Power Plug Gas Valve Pilot Burner with ODS X4 X5 X1 SW1 Back up Battery Case ...

Страница 19: ...as supply The dimensions to the center of this opening are shown below NOTE The knockout must be sealed off after being taken off to prevent air from the walls shutting off the pilot light If the gas and electrical lines cannot be run to the provided knockouts a seperate hole may be drilled to bring gas and electrical into the unit This hole must be located below the hearth tray and sealed complet...

Страница 20: ...owing limits MUST be maintained for installations of these fireplaces The bottom of the cabinet may be no closer to the room ceiling than 36 The minimum interior height of an enclosing chase is 263 4 The combustible facing limits for the H Series Vent Free Gas Fireplaces are listed in the table above Combustible wall facing is NOT permitted inside this limit Dimension B is measured up from the top...

Страница 21: ... be considered when choosing any fasteners paint mastic sealant caulk etc for use in this area as materials may change color or emit an odor when heated Petroleum based tile adhesives should be avoided and thin set mortar used instead The fire media must be installed per these instructions This heater must use only the fire media provided by European Home An excess amount of fire media may adverse...

Страница 22: ...the unit This is normal and is a result of the burn off of the lubricants and sealants used when manufacturing the fireplace We recommend that you open the nearby windows for extra ventilation and operate the fireplace for at least four hours During this first fire examine the flame for appearance and quality Examine the burner media for sooting The flames should look like those on page 24 Since i...

Страница 23: ...these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life 1 STOP Read the safety information above 2 This appliance is equipped with an ignition device which auto matically lights the pilot Do not try to light the pilot by hand 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow ...

Страница 24: ...d Burner With all parts of the fireplace at room temperature carefully remove and clean the fire media with a soft bristled brush Lift off the hearth panel and clean the burner surface with a brush and clean the rest of the burner module including the pilot burner with a vacuum cleaner After lifting off the Hearth Panel ensure that the Primary Air Openings shown below at the end of each Burner Inl...

Страница 25: ...eries Vent Free Parts List ITEM PART NO SIT Proflame NG Gas Valve HVF GS GV 01 SIT Proflame Control Module HVF GS CM 01 SIT Proflame Remote Control HVF GS TX 01 H Series NG Pilot Assembly HVF GS PA 01 with Oxygen Depletion Sensor ODS Carrara Pebbles Fire Media HVF FM WHTP 1 2 Black Glass Fire Media FM CG BLACK HVF 42 Fireplace Screen HVF 42 SA SDS IM 01 HVF 60 Fireplace Screen HVF 60 SA SDS IM 01 ...

Страница 26: ... from new or serviceable used parts and is at least functionally equivalent to the original product A replacement product part assumes the remaining warranty of the original product or ninety 90 days from the date of replacement or repair whichever provides longer coverage for you When a product or part is exchanged any replacement item becomes your property and the replaced item becomes the prope...

Страница 27: ...oltage readings Press the Red SW1 button the on the IFC module You should hear 3 fast beeps indicating the receiver box is ready to learn the remote code Did you hear the beep code Attempt learn sequence again If no sound LED replace IFC module No Yes Quickly press the ON OFF power button on the remote control You should now hear 4 beeps indicating the receiver has learned the remotes unique progr...

Страница 28: ...ot assembly for proper grounding 6 Check continuity of valve coil If no continuity replace valve 7 Verify proper voltage at pilot valve connection If voltage is present and no gas released replace valve If no voltage is present replace IFC board Is piezo still sparking Yes 1 Verify flame sensor is in the pilot flame adjust flame as needed 2 Verify flame sensor wire is properly connected to module ...

Страница 29: ...eiver switch is in ON position If equipped verify receiver switch is powered ON and thermostat is OFF 2 Verify electrical connections are properly connected according to the wiring diagram and replace any damaged harnesses 3 Verify the pilot flame is properly directed to ignite the burner 4 Verify piezo is not sparking if so go back to Piezo Still Sparking 5 Verify proper components are installed ...

Страница 30: ...nections and inspect wiring for damage 4 Inspect main burner orifice for blockage and correct size 5 Verify receiver is receiving transmitter command by beeping If no beep see Remote Receiver Not Synchronized 6 Check continuity of step motor Resistance between yellow orange and black brown wires should be 25 ohms If no continuity or step motor is not regulating out pressure replace step motor Yes ...

Страница 31: ...justment When using a home automation system 1 Remove the jumper wire A from the Jumper Block B located at X4 using a small flathead screw driver Replace it with a millivolt rated dry contact closure DCC provided by you 2 The remote control must then be disconnected from the system by pressing the SW1 button see above TWICE in succession IFC Control Module Power Plug Gas Valve Pilot Burner X4 X5 X...

Страница 32: ...F SA ASK 01 is available for the H Series Vent Free Gas Fireplace the installation of which may be required by your local building code Confirm the installation requirements with your local inspector prior to ordering and installing the Air Shutter Kit It is recommended that the Air Shutter Kit ASK be installed before the final framing of the fireplace as the ASK increases a dimension of the firep...

Страница 33: ...ing with a Slip Tab on each end 2 Slip Tabs will slide between the ceiling panel and the upper inside frame of the fireplace using a magnet to secure Space the Slip Tabs 6 152mm to 12 305mm apart starting with a Slip Tab on each end 3 The bottom of the screen will sit on the fireplace base and rest up against the tabs and the magnets Push the top of the screen into place so that the top of the met...

Страница 34: ...the 4 holes on the deflector panel as shown below Center the deflector in the center top of the unit so there is equal space on either side and the bend of the deflector lined up with the front of the unit Screw the deflector up to the underside using the 4 included screws starting at either end first to align the deflector then the middle screws In the end the unit should look like the below imag...

Страница 35: ......

Страница 36: ...36 H Series Vent Free Fireplace Rev 12042020 EuropeanHome com IGHVFT11 180815 EUROPEAN HOME a division of Europa Ja Inc 30 Log Bridge Road Building 300 Suite 303 Middleton MA 01949 www europeanhome com ...

Отзывы: