5.3 - TROUBLE SHOOTING
Signals to the operator
SIGNAL
CAUSE
SOLUTION
The led flashes orange
The machine is heating and the
temperature is not sufficient for correct
sealing.
Wait for the fixed green light
when the machine is ready to
be used.
The led is flashing orange and there
is an intermittent acoustic signal.
The sealing handle has been lowered
during the heating phase and the device is
not yet ready.
Lift up the handle and wait
until the led becomes fixed
green.
The led is flashing orange and there
is an intermittent acoustic signal.
The maximum sealing time has been
exceeded and the handle has remained
down.
Lift the handle immediately.
The led is flashing red.
The device has broken down.
Call technical assistance.