Item WoodLand 2000
Unit
Heat output
Type of heat input, for electric storage local space
heaters only (select one)
Nominal
heat output
P
nom
2.0
KW
manual heat charge control, with
integrated thermostat
Not applicable
Minimum
heat output
(indicative)
P
min
1.0
KW
manual heat charge control with
room and/or outdoor temperature
feedback
Not applicable
Maximum
continuous
heat output
P
max
,
c
2.0
KW
electronic heat charge control with
room and/or outdoor temperature
feedback
Not applicable
Auxiliary electricity consumption
fan assisted heat output
Not applicable
At nominal
heat output
el
max
0.014
KW
Type of heat output/room temperature control
(select one)
At minimum
heat output
el
min
0.014
KW
single stage heat output and no
room temperature control
[no]
In standby
mode
el
SB
0.48
W
Two or more manual stages, no
room temperature control
[no]
with mechanic thermostat room
temperature control
[no]
with electronic room temperature
control
[no]
electronic room temperature control
plus day timer
[no]
electronic room temperature control
plus week timer
[yes]
Other control options (multiple selections possible)
room temperature control, with
presence detection
[no]
room temperature control, with open
window detection
[no]
with distance control option
[no]
with adaptive start control
[yes]
with working time limitation
[no]
with black bulb sensor
[no]