00121017, Version 1.0
27/40
Mounting on a stand
For mobile use, place the light set on a lighting stand via the stand sleeve and fasten the fixation screw.
Suitable stands can be found in chapter Accessories.
Notes:
•
Please make sure the load is installed in a balanced way and the carrying capacity of the stand is not
exceeded.
•
Install the stand on a plane area (inclination angle max. 5°) and out of the reach of people.
•
Depending upon the individual installation spot, all necessary measures against movement and for
securing the standing safety have to be created (also in case of fire).
CONNECTIONS
Connection to the mains
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1 Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
2 To switch off the unit, disconnect the power plug.
3 Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
Power supply of further devices
The jack POWER OUT allows for power supply of further devices. To interconnect several devices, connect
the jack POWER OUT to the input POWER IN of the next unit until all units are connected. Matching power
cables with IEC plugs are available as accessories. In this manner, up to 8 devices can be linked at 230/240
input voltage and up to 4 devices at 110/115 input voltage.
Содержание LED KLS Laser Bar PRO FX
Страница 39: ......