00041808.DOC, Version 1.1
11/11
Connection with the mains
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Make sure that the outlet is in a dry area.
OPERATION
After you connected the garden luminaire to the mains, the lamps start burning.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
5 W max.
Protection grade:
IP 44
Number of LEDs:
200
Dimensions (LxH):
approx. 400 x 400 mm
Weight:
approx. 1.9 kg
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
B
(steady state):
50° C
Min. distance from flammable surfaces:
0.5 m
Min. distance to lighted object:
0.1 m
Please note: Every information is subject to change without prior notice. 15.04.2009 ©