00057587.DOC, Version 1.0
22/27
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Please note:
A maximum of 8 EUROLITE 4 x PAR-36 TCL LED Audience Blinder may be linked together.
After every 8 devices, the fixtures must have a renewed connection with the power mains.
OPERATION
After you connected the spot to the mains, the EUROLITE 4 x PAR-36 TCL LED Audience Blinder starts
running.
The LCD display lights up and you can choose the desired mode via the MODE button:
- STAND-ALONE MODE
- AUTO MODE
- DMX MODE
- MASTER/SLAVE MODE
- SOUND CONTROL MODE
STAND-ALONE MODE
Chaser
A chaser is a sequence of different steps that will be called up one after another in a continuous loop. With
the 4 x PAR-36 TCL LED Audience Blinder, you can select up to 14 different chasers.
Selecting a chaser
Press the MODE button to select the internal program mode. Select the desired chaser (P01 – P14) via the
UP or DOWN buttons (see following graphic).
Press the ENTER button to select speed and flash settings, respectively. You can select the desired values
via the UP or DOWN buttons.
Speed from 00 to 99, increasing.
Flash from 00 to 99, increasing.
Please press the ENTER button to confirm and to exit the STAND-ALONE Mode.