![Euroheat Harmony 44 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/euroheat/harmony-44/harmony-44_installation-and-servicing-instructions-manual_2437726008.webp)
©
EUROHEAT
DISTRIBUTORS (H.B.S) LTD. June 2009
E & OE Instructions Part Number IN1113 Ed. E
7
Suitably approved cowl
to prevent ingress of rain,
birds and/or to assist with
flue stabilization
Flue liner support collar
Weatherproof chimney
capping and pot
Sound chimney brick work
Stainless steel liner
Flexible to single wall
adapter
Register plate preventing the
escape of heat, positioned as low
as practicable to aid convection.
There must be an access door
to facilitate debris removal and
inspection.
Sufficient clearance behind
stove for maintenance
Level and stable supporting
hearth
Ridged section of flue pipe
Example of Stove Fitted into an Existing Chimney
For further information on flues ask you retail outlet for Technical Document IN1087 The Flue, or if the
installation is to be into a pre cast flue Technical Bulletin 118.
X
Height of flue less than 3 meters
Height of flue greater than 3 meters
The example above shows an
unacceptable installation into an
unsound and unlined flue. The height
is less than 3 meters and there is no
cowl.