background image

Fig. 20

5. The HEPA filter may 

also be washed by 
running it under 
the tap allowing 
the water to run on 
the dirty side. 
(Fig. 18) We 
recommend 
washing it once a 
month or when 
suction appears reduced. Always 
allow 24 hours for air drying before 
replacing into the vacuum.

Please Note

: The white material in the 

HEPA filter will discolor over time - This is 
NORMAL and will NOT affect the 
performance of the filter.

Fig. 18

WARNING

:

Never over fill the 

dust cup - remove dirt and clean 

the HEPA dust cup filter, filter ring and 
debris screen each time the dust cup is 
emptied during prolonged usage or risk 
motor damage. 

OPERATING INSTRUCTIONS

7

Pre-

Motor 

Filter 

Cover

Fig. 21

Fig. 22

5. To clean the pre-motor filters, rinse in 

lukewarm water and let air dry 
completely for 24 hours. Do not use a 
washing machine to rinse the filters. 
Do not use a hair dryer to 
dry them. Air dry only. 
Never operate the 
vacuum cleaner without 
all filters in place. 

6. We recommend washing 

the pre-motor filters when 
you are washing your 
HEPA filter. (Fig. 22)

Cleaning the Filter Ring

1. Around the HEPA filter 

there is a filter ring.  
This is washable in 
lukewarm water. 
(Fig. 19) To remove 
the filter ring, slide it 
off the HEPA filter.

2. We recommend 

washing the filter ring 
when you are 
washing your HEPA 
filter. Always allow the 
filter ring to air dry for 
24 hours before replacing onto 
the HEPA filter. Never run the vacuum 
without all the filters in place. 

Note:

This is a washable filter, but we 

recommend replacing it every three (3) 
months. 

Fig. 19

2. Make sure that the filter frame is 

completely dry before replacing into 
the dust cup. Always air dry for 24 
hours.

Cleaning the Pre-Motor Filters

1. Underneath the dust cup container, 

are two pre-motor filters. (Fig. 21)

2. One is small and it fits into the air inlet 

pipe.

3. To remove, just lift out. 
4. To remove the second pre-motor filter, 

twist the pre-motor filter cover, lift the 
cover out and remove the second pre-
motor filter. (Fig. 21)

Cleaning the HEPA Filter Frame

1. Before replacing the HEPA filter in 

the HEPA Filter frame, you can 
(should) rinse the frame in lukewarm 
water by just running it under the tap 
to remove any dust that is adhering 
to the frame.  (Fig. 20) Do 

NOT

place 

in dishwasher.

CONSIGNES D’UTILISATION

Enroulage et Déroulage du 

32

Cordon d’Alimentation.

Cet appareil est doté
d’une fonction 
pratique de 
rangement du cordon.
Le cordon 
d’alimentation 
s’enroule autour 
des deux porte-
cordons latéraux 
de l’appareil.
Le porte-cordon 
supérieur est doté 
d’une fonction de 
relâche rapide.
Tournez le crochet 
du cordon vers la gauche ou vers la 
droite pour retirer le cordon 
d’alimentation. (Fig. 12)

Fig. 12

Vidange du Réservoir de la 
Coupelle à Poussière

AVERTISSEMENT:

Débranchez toujours l’appareil 
avant d’ouvrir la coupelle à 
poussière (réservoir).

Important:

N’utilisez pas 

l’aspirateur 

sans son filtre HEPA.

1. Pour retirer la 

coupelle de 
l’aspirateur, 
appuyez sur 
son bouton 
de relâche et 
retirez-la. 
(Fig. 13)

2. Pour vider le 

réservoir de la 
coupelle, tenez-la 
par la poignée au-
dessus d’un sac de 
poubelle et 
appuyez sur le 
bouton de relâche 
de la trappe situé à 
l’arrière. Ceci 
ouvrira le fond de la 
coupelle. (Fig. 14)

Fig. 14

Fig. 13

Fig. 16

AVERTISSEMENT

:

Après 

chaque utilisation - retirez 

toujours le jeu de filtre, « secouez » le 
filtre HEPA et retirez tous les débris 
du filtre à débris.

Important: 

Le filtre de coupelle à 

poussière HEPA rinçable et « secouable » 
empêchera la plus petite particule de 
poussière et les allergènes en suspension 
de revenir dans l’air que vous respirez. En 
fait, il retient 99,97 % des particules,qui 
sont aussi petites que 0,3 micromètres –
beaucoup plus petites qu’un cheveu! 
Étant donné ce pouvoir filtrant incroyable, 
le filtre HEPA accumule rapidement les 
fines particules de poussière à l’intérieur 
de son pli de filtre blanc. Ces particules 
sont difficiles à voir mais elles obstrueront 
ou réduiront éventuellement le pouvoir de 
succion si le filtre n’est pas nettoyé 
correctement. Nettoyez le filtre HEPA 
après chaque utilisation, tel que décrit 
dans cette section.

Nettoyage du Filtre de Coupelle à 
Poussière HEPA

1. Pour retirer le filtre 

HEPA, retirez la 
coupelle de l’appareil. 

2. Pour retirer le  couvercle 

de la coupelle, tenez la 
coupelle par sa 
poignée, tournez-la 
dans le sens horaire 
et retirez son couvercle. 
(Fig. 15)

3. Retirez le filtre HEPA 

rinçable et lavable à 
l’eau de la coupelle. 
(Fig. 16)

4. Retirez l’anneau du 

filtre HEPA.« Secouez » 
vigoureusement le 
filtre de coupelle 
HEPA sur une 
surface solide jusqu’à 
ce que plus aucune 
poussière ne s’en 
échappe. (Fig. 17)

Fig. 15

Fig. 17

Содержание SHARK V1310PT

Страница 1: ...parateur non autoris par EURO PRO Operating LLC Cette garantie couvre l acheteur initial du produit et exclut toute autre garantie juridique ou conventionnelle Le cas ch ant EURO PRO Operating LLC n e...

Страница 2: ...unattended while connected 9 Keep hair loose clothing fingers and all parts of body away from opening and moving parts 10 Do not use to pick up flammable or combustible liquids such as gasoline or use...

Страница 3: ...R initialisez le disjoncteur ou remplacez le fusible L aspirateur n aspire pas 1 Coupelle pleine ou obstru e 2 Mauvais r glage de la hauteur des poils 3 Bec obstru 4 Orifice d entr e de poussi re obst...

Страница 4: ...oucement l appareil 16 Remplacer la plaque inf rieur en vissant les quatre 4 vis externes en premier 17 Pour visser la vis du centre tenir le bouton de r glage de la hauteur du tapis de l ext rieur et...

Страница 5: ...et levez le panneau de l lectrobrosse en prenant appui l arri re de l lectrobrosse Fig 29 Fig 29 La courroie d entra nement du bec souffleur doit tre remplac e occasionnellement La fr quence varie sel...

Страница 6: ...ppareil refroidi pendant 45 minutes branchez le et appuyez sur le bouton On Off L aspirateur devrait red marrer Si l aspirateur ne d marre toujours pas contactez le service la client le au 1 866 826 6...

Страница 7: ...ance AVERTISSEMENT Videz toujours la coupelle et nettoyez toujours le filtre HEPA et le filtre d bris avant chaque utilisation et pendant l usage prolong Ne faites jamais d border la coupelle Retirez...

Страница 8: ...adhering to the frame Fig 20 Do NOT place in dishwasher CONSIGNES D UTILISATION Enroulage et D roulage du 32 Cordon d Alimentation Cet appareil est dot d une fonction pratique de rangement du cordon...

Страница 9: ...anchez le avant de r gler la hauteur du tapis Le devant de l aspirateur pr sente une poign e qui l ve et abaisse l lectrobrosse motoris e afin de correspondre au type de tapis Pendant que l aspirateur...

Страница 10: ...a Philips screw driver remove the four 4 screws that attach the base plate to the lower plate Fig 27 4 After you have removed the base plate remove the remaining five 5 screws from the lower plate us...

Страница 11: ...lug from wall outlet 2 With a flat head screw driver snap off the lens cover by pressing down on the two notches on the lens cover Fig 31 3 Lift off the head light lens 4 Remove the light bulb by pull...

Страница 12: ...er Brush Does Not Rotate Or Rotates Slowly 1 Rotating brush turbine or elbow obstructed 2 Belt broken 3 Hose obstructed 4 HEPA filter clogged 1 Clear obstructions 2 Call Customer Service 3 Clear obstr...

Страница 13: ...de tout ce qui pourrait r duire le d bit d air Rangez l appareil l int rieur dans un endroit frais et sec Assurez vous que votre espace de travail est bien clair Gardez votre visage et votre corps l a...

Страница 14: ...ode Model V1310PT 13 Model V1310PT Impreso en China GARANT A LIMITADA DE UN 1 A O EURO PRO Operating LLC garantiza este producto contra defectos de materiales y mano de obra por un t rmino de un 1 a o...

Страница 15: ...el sistema desatendido mientras est enchufado 9 Mantenga el cabello la ropa suelta los dedos y toda parte del cuerpo alejados de las aberturas y de las partes m viles 10 No utilizar para recoger l qui...

Страница 16: ...encendido una vez 4 Recomponer el termostato del motor 5 Recomponer la llave t rmica o cambiar el fusible Aspiradora no absorbe 1 Recipiente de la tierra lleno o tapado 2 Ajuste de altura inadecuado 3...

Страница 17: ...Presi nelo firmemente para asegurarse de que est insertado completamente 13 Verifique que la correa est centrada en la polea del agitador y que el cepillo pueda girar 14 Vuelva a colocar la cubierta...

Страница 18: ...ar la base quite los cinco 5 tornillos restantes de la placa inferior con un destornillador Philips Fig 28 Base Placa inferior Fig 28 Limpieza del Mango de la Manguera Si contin a notando una reducci...

Страница 19: ...rre la cubierta superior del cepillo y deslice la palanca de traba hacia atr s para trabar la cubierta Fig 11 INSTRUCCIONES DE USO Termostato del Motor Importante Esta unidad est equipada con un termo...

Страница 20: ...erficie dura hasta que no salga m s tierra Fig 17 Fig 15 ADVERTENCIA Siempre vac e el recipiente de la tierra y limpie el filtro HEPA y el filtro de deshechos luego de cada uso y durante usos prolonga...

Отзывы: