![EUCHNER CES-I-BR Series Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/euchner/ces-i-br-series/ces-i-br-series_operating-instructions-manual_2434840028.webp)
Operating Instructions
Non-Contact Safety Switch CES-I-BR-.-C07-…
28
(translation of the original operating instructions) 2510145-02-07/18
11.3. Technical data of actuator CES-A-BDN-06-158210
Parameter
Value
Unit
min.
typ.
max.
Housing material
Macromelt PA-based plastic
Dimensions
26 x
∅
6
mm
Weight
0.005
kg
Ambient temperature
- 40
-
+ 70
°C
Degree of protection acc. to EN IEC 60529
IP 65/IP 67/IP 69/IP 69K
1)
Installation position
Active face opposite read head
Power supply
Inductive via read head
1) With flush installation
11.3.1. Dimension drawing
Installation options
26
0
+0,5
Ø
30
* min.
30 *
30 *
6,1
0
+0,1
6
* Metal-free zone
Operating distance
Approach
direction
CAUTION
Ì
Do not mount at temperatures below 0 °C.
Ì
The actuator can be damaged during mounting.
11.3.2. Switching distances
Operating distance for center offset m = 0
Approach direction
Parameter
Value
Unit
A
min.
typ.
max.
z
x
Switch-on distance
-
16
-
mm
Assured switch-on distance s
ao 1)
13
-
-
Switching hysteresis
1)
1
2
-
Assured switch-off distance s
ar
- in x direction
-
-
24
1) The values apply to surface installation of the actuator
Approach direction
Parameter
Value
Unit
C
min.
typ.
max.
z
x
Switch-on distance
-
11
-
mm
Assured switch-on distance s
ao
1)
6
-
-
Switching hysteresis
1)
1
2
-
Assured switch-off distance s
ar
- in x direction
-
-
21
1) The values apply to surface installation of the actuator