![EUCHNER CES-I-BR Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/euchner/ces-i-br-series/ces-i-br-series_operating-instructions-manual_2434840022.webp)
Operating Instructions
Non-Contact Safety Switch CES-I-BR-.-C07-…
22
(translation of the original operating instructions) 2510145-02-07/18
11. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
11.1. Technical data of safety switch CES-I-BR-C07-…
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT plastic
Dimensions
40 x 26.5 x 18
mm
Weight (device without connection cable)
0.08
kg
Ambient temperature at U
B
= DC 24 V
- 25
-
+ 55
°C
Storage temperature
- 40
-
+ 70
Degree of protection
IP 65/IP 67/IP 69/IP 69K
Safety class
III
Degree of contamination
3
Installation position
Any
Installation method
Non-flush
Connection
Plug connector M12, 8-pin
Operating voltage U
B
(regulated, residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption
40
mA
External fuse (operating voltage)
0.25
-
8
A
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(FO1A)/U(FO1B)
1)
HIGH
U(FO1A)
U
B
-1.5
-
U
B
V DC
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
0
1
Switching current per safety output
1
-
150
mA
Utilization category according to EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Off-state current I
r
≤
0.25
mA
Monitoring output OD/C
1)
p-switching, short circuit-proof
- Output voltage
HIGH
U
B
-1.5
-
U
B
V DC
LOW
0
-
1
- Switching current
1
-
50
mA
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
≤
10
%
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay
-
5
-
s
Risk time for single device
-
-
125
ms
Risk time delay per device
10
ms
Switch-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
0.3
ms
Test-pulse interval
Approx. 100
ms
Reliability values acc. to EN ISO 13849-1:2015
Category
4
Performance Level
PL e
PFH
D
6 x 10
-10
/ h
Mission time
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.