EUCHNER CES-I-BR Series Скачать руководство пользователя страница 23

23

2510145-02-07/18 (translation of the original operating instructions)

Operating Instructions

Non-Contact Safety Switch CES-I-BR-.-C07-…

EN

11.1.1. Radio frequency approvals
FCC ID:  2AJ58-01
IC: 

  22052-01

FCC/IC-Requirements

This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject 

to the following two conditions:
1)  This device may not cause harmful interference, and
2)  this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority 

to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment 

is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required 

to correct the interference at his own expense.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploi-

tation est autorisée aux deux conditions suivantes : 
(1) l’appareil ne doit pas produire de brouillage, et 
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 

compromettre le fonctionnement.

Содержание CES-I-BR Series

Страница 1: ...EN Operating Instructions Non Contact Safety Switch CES I BR C07 Unicode Multicode ...

Страница 2: ...about 10 8 2 Safety in case of faults 10 8 3 Fuse protection for power supply 10 8 4 Requirements for connection cables 10 8 5 Maximum cable lengths 11 8 5 1 Determining cable lengths using the example table 12 8 6 Pin assignment of safety switch CES I BR 13 8 7 Pin assignment of Y distributor 14 8 8 Connection of a single BR device 15 8 9 Connection of several devices in a switch chain 16 8 10 No...

Страница 3: ... 1 2 Typical system times 24 11 1 3 Dimension drawing for safety switch CES I BR C07 24 11 2 Technical data of actuator CES A BTN C07 25 11 2 1 Dimension drawing 25 11 2 2 Operating distances and approach directions 26 11 3 Technical data of actuator CES A BDN 06 158210 28 11 3 1 Dimension drawing 28 11 3 2 Switching distances 28 12 Ordering information and accessories 29 13 Inspection and service...

Страница 4: ... CD DANGER WARNING CAUTION Safety precautions Danger of death or severe injuries Warning about possible injuries Caution slight injuries possible NOTICE Important Notice about possible device damage Important information Tip Useful information 1 4 Supplementary documents The overall documentation for this device consists of the following documents Document title document number Contents Safety Inf...

Страница 5: ...duction Ì Ì IEC 62061 Safety of machinery Functional safety of safety related electrical electronic and programmable electronic control systems Correct use includes observing the relevant requirements for installation and operation particularly based on the following standards Ì Ì EN ISO 13849 1 Safety of machinery Safety related parts of control systems Part 1 General principles for design Ì Ì EN...

Страница 6: ...s the safe function of the guard should be checked at suitable intervals as part of the mainte nance schedule WARNING Danger to life due to improper installation or due to bypassing tampering Safety components fulfill a personnel protection function Ì Ì Safety components must not be bypassed turned away removed or otherwise rendered ineffec tive On this topic pay attention in particular to the mea...

Страница 7: ...rd is closed the actuator is moved towards the safety switch When the switch on distance is reached power is supplied to the actuator by the switch and data are transferred If a permissible code is detected the safety outputs are switched on The safety outputs are switched off when the guard is opened In the event of a fault in the safety switch the safety outputs are switched off and the DIA LED ...

Страница 8: ...as a function of the material used for the guard Ì Ì Observe direction of arrow on the device see figure below Permissible approach directions B A C D z x y x z y B A C D z x y x z y Note the following points Ì Ì Actuator and safety switch must be easily accessible for inspection and replacement Ì Ì Actuator and safety switch must be fitted so that a minimum distance is maintained with a side appr...

Страница 9: ...must be positive switching as the two outputs on the safety switch deliver a level of 24 V in the switched on state Ì Ì All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC 61558 2 6 with limited output voltage in the event of a fault or by other equivalent isolation measures PELV Ì Ì All electrical outputs must have an adequate prot...

Страница 10: ...ch Ì Ì A short circuit in the cable can be excluded by laying the cable with protection 8 3 Fuse protection for power supply The power supply must be provided with fuse protection depending on the number of switches and current required for the outputs The following rules apply Max current consumption of an individual switch Imax Imax IUB IOD IFO1A FO1B IUB Switch operating current 40 mA IOD Load ...

Страница 11: ...between two switches is limited to 100 m SPS PLC l1 l2 lmax 200 m ln umin 24 V 5 x 0 34 mm2 5 x 0 34 mm2 5 x 0 34 mm2 CES I BR n CES I BR n 1 CES I BR 1 iout n Max number of switches IOD mA Possible output current per channel FO1A FO1B l1 m Max cable length from the last switch to the control system 0 34 mm 5 10 100 25 100 50 80 100 50 200 25 6 10 100 25 90 50 70 100 50 200 25 10 10 70 25 60 50 50...

Страница 12: ... example with six CES I BR A safety relay is connected downstream which consumes 75 mA at each of the two safety inputs All the relevant values can now be determined using the example table 1 Select the corresponding section in the column n max number of switches Here six switches 2 In column IOD possible output current per channel FO1A FO1B find a current greater than or equal to 75 mA Here 100 m...

Страница 13: ... 3 2 8 8 2 7 6 1 3 4 5 UB 0V FI1A FI1B FO1A FO1B OD C nc View of connection side on the safety switch Figure 2 Pin assignment of safety switch CES I BR Pin Designation Description 1 FI1B Enable input for channel 2 2 UB Power supply DC 24 V 3 FO1A Safety output channel 1 4 FO1B Safety output channel 2 5 OD C Monitoring output communication 6 FI1A Enable input for channel 1 7 0V Ground DC 0 V 8 nc n...

Страница 14: ...1 UB X3 2 FI1A X3 3 0 V X3 4 FI1B X3 5 RST 12 12 097627 45 15 1 4 8 5 6 3 1 2 7 35 1 20 5 1 2 4 5 3 3 4 2 1 5 M x1 Ø 14 6 M x1 Y distributor 097627 Socket Pin assignment of safety switch CES I BR 8 pin plug and Y distributor 8 pin socket Pin Function X1 1 FI1B X1 2 UB X1 3 FO1A X1 4 FO1B X1 5 OD X1 6 FI1A X1 7 0 V X1 8 RST pin Socket M12x1 44 45 41 15 M12x1 15 15 M12x1 33 A B 4 8 5 6 3 1 2 7 1 2 4...

Страница 15: ... always be evaluated Important The example shows only an excerpt that is relevant for connection of the CES system The example illustrated here does not show complete system planning The user is responsible for safe integration into the overall system Detailed application examples can be found at www euchner com Simply enter the order number in the search box All available connection examples for ...

Страница 16: ...n examples for the device in Downloads The series connection is shown here based on the example of the version with plug connectors M12 The switches are con nected one behind the other with the aid of pre assembled connection cables and Y distributors If a safety door is opened or if a fault occurs on one of the switches the system shuts down the machine A higher level control system cannot howeve...

Страница 17: ...stributor Y distributor Y distributor Terminating plug Eval Unit Safety Outputs Safety Inputs Safety Inputs Safety Outputs Read Head 5 OD C 4 FO1B 2 UB 8 nc 6 FI1A 1 FI1B 7 0V 5 OD C 3 FO1A 4 FO1B 2 UB 8 nc 6 FI1A 1 FI1B 7 0V 3 FO1A 4 FO1B 2 UB 8 nc 6 FI1A 1 FI1B 7 0V 5 OD C 3 FO1A 0V 24V CES CES CES Read Head Read Head Figure 4 Connection example for series connection ...

Страница 18: ...to outputs FO1A and FO1B of another EUCHNER BR device series connection Pulsed signals must not be present at inputs FI1A and FI1B Ì Ì The safety outputs FO1A and FO1B can be connected to the safe inputs of a control system Prerequisite the input must be suitable for pulsed safety signals OSSD signals e g from light grids The control system must tolerate test pulses on the input signals This norma...

Страница 19: ... the safety switch only after a third code has been taught in Ì Ì The safety switch can be operated only with the last actuator taught in Ì Ì The number of teach in operations is unlimited Ì Ì If the switch detects the actuator that was most recently taught in when in the teach in standby state this state is ended immediately and the switch changes to normal operation Ì Ì If the actuator to be tau...

Страница 20: ...llation and any fault the safety function must be fully checked Proceed as follows 1 Switch on operating voltage The machine must not start automatically The safety switch carries out a self test The green STATE LED flashes for 5 s at 5 Hz The green STATE LED then flashes at regular intervals 2 Close all guards The machine must not start automatically The green STATE LED illuminates continuously 3...

Страница 21: ...ve acknowledgment after completion of teach in operation Fault display X off X 1 x Fault in the teach in operation only unicode actuator removed from the operating dis tance prior to the end of the teach in operation or faulty actuator detected X off off 2 x Input fault e g missing test pulses illogical switch state from previous switch in the switch chain X off off 3 x Defective or incompatible a...

Страница 22: ... voltage U FO1A U FO1B 1 HIGH U FO1A UB 1 5 UB V DC HIGH U FO1B LOW U FO1A U FO1B 0 1 Switching current per safety output 1 150 mA Utilization category according to EN IEC 60947 5 2 DC 13 24 V 150 mA Caution outputs must be protected with a free wheeling diode in case of inductive loads Off state current Ir 0 25 mA Monitoring output OD C 1 p switching short circuit proof Output voltage HIGH UB 1 5...

Страница 23: ...Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicatio...

Страница 24: ...ched off after the risk time at the latest If several devices are operated in a series connection the risk time of the overall device chain will increase with each device added Use the following calculation formula tr tr e n x tl tr Total risk time tr e Risk time single device see technical data tl Risk time delay per device n Number of additional devices total number 1 Discrepancy time The safety...

Страница 25: ...N C07 Parameter Value Unit min typ max Housing material PBT plastic Dimensions 42 x 25 x 18 mm Weight 0 03 kg Ambient temperature 40 70 C Degree of protection IP 65 IP 67 IP 69 IP 69K Installation position Active face opposite read head Power supply Inductive via read head 11 2 1 Dimension drawing Active face NOTICE Ì Ì Two safety screws M4x20 included Ì Ì Covers are included ...

Страница 26: ...10 14 18 22 26 Switching distances on approach in x direction without center offset z y 0 Parameter Value Unit min typ max Switch on distance 13 mm Assured switch on distance sao 10 Switching hysteresis 1 1 2 Assured switch off distance sar 20 Typical operating distance in approach direction B 18 26 2 6 14 10 22 22 26 18 2 6 10 6 10 2 1 4 2 6 1 0 Z Z Y X Y X Y X Z 2 6 10 14 2 6 10 14 2 6 10 2 6 10...

Страница 27: ...out center offset z y 0 Parameter Value Unit min typ max Switch on distance 7 mm Assured switch on distance sao 3 Switching hysteresis 1 1 2 Assured switch off distance sar 17 Typical operating distance in approach direction D Z 2 6 2 2 6 10 2 6 1 0 Y X 10 14 18 6 10 22 22 18 Y Z X X Z Y 2 6 10 2 6 10 2 6 10 14 18 22 2 6 10 14 18 22 2 6 10 2 6 10 Switching distances on approach in x direction with...

Страница 28: ...0 0 5 Ø 30 min 30 30 6 1 0 0 1 6 Metal free zone Operating distance Approach direction CAUTION Ì Ì Do not mount at temperatures below 0 C Ì Ì The actuator can be damaged during mounting 11 3 2 Switching distances Operating distance for center offset m 0 Approach direction Parameter Value Unit A min typ max z x Switch on distance 16 mm Assured switch on distance sao 1 13 Switching hysteresis 1 1 2 ...

Страница 29: ...ccessories or spare parts that can be ordered from EUCHNER may be replaced Regular inspection of the following is necessary to ensure trouble free long term operation Ì Ì Check the switching function see chapter 9 3 Functional check on page 20 Ì Ì Check the secure fastening of the devices and the connections Ì Ì Check for soiling No servicing is required Repairs to the device are only allowed to b...

Страница 30: ...Operating Instructions Non Contact Safety Switch CES I BR C07 30 translation of the original operating instructions 2510145 02 07 18 15 Declaration of conformity ...

Страница 31: ...31 2510145 02 07 18 translation of the original operating instructions Operating Instructions Non Contact Safety Switch CES I BR C07 EN ...

Страница 32: ...chner com Edition 2510145 02 07 18 Title Operating Instructions Non Contact Safety Switch CES I BR C07 translation of the original operating instructions Copyright EUCHNER GmbH Co KG 07 2018 Subject to technical modifications no responsibility is accept ed for the accuracy of this information ...

Отзывы: