System Manual Safety Switch CES-AP-C.2-CH
8
Mounting
Caution!
Risk of damage to equipment as a result of incorrect installation. Safety switches
must not be used as a mechanical end stop.
Fit an additional end stop for the movable part of the safety guard.
Important!
From the assured switch-off distance S
ar
, the safety outputs are safely shut
down.
When mounting several safety switches, observe the stipulated minimum
distance to avoid mutual interference.
min. 400 mm
The operating distance changes during the mounting of the actuator as a
function of the material used for the safety guard.
Note the following points:
Actuator and safety switch must be easily accessible for inspection and re-
placement.
The switching operation must only be triggered by the specific actuator desig-
nated for this purpose. For permissible combinations please see the table of
possible combinations on page 4.
Actuator and safety switch must be fitted so that
the front faces are at the minimum switch-on distance 0.8 x S
ao
or closer
when the safety guard is closed (see section Operating distances). A mini-
mum distance dependent on the actuator must be maintained for a side ap-
proach direction:
- For CES-A-BLN-R
6 mm
- For CES-A-BLN-L
6 mm
- For CES-A-BLN-U
6 mm
- For CES-A-BDN
10 mm
when the safety guard is open up to the distance S
ar
(assured switch-off dis-
tance), a hazard is excluded.
the actuator is positively mounted on the safety guard, e.g. by using the
safety screws included.
Pay attention to the maximum tightening torque for the safety switch and
actuator mountings of 1 Nm.
Installation options
Installation options