
Operating Instructions
Non-Contact Safety Switch CES-A-C5H-EX
24
(Translation of the original operating instructions) 2110182-10-02/20
13.1.2. Typical system times
Refer to the technical data for the exact values.
Ready delay
: After switch-on, the device carries out a self-test. The system is ready for operation only after this time.
Turn-on time of safety outputs
: The max. reaction time t
on
is the time from the moment when the actuator is in the actu-
ating range to the moment when the safety outputs switch on. This time corresponds to the risk time.
Risk time according to EN 60947-5-3
: If an actuator moves outside the actuating range, the safety outputs (LA and LB)
are deactivated at the latest after the risk time.
Discrepancy time
: The safety outputs (LA and LB) switch with a slight time offset. They have the same signal state no
later than after the discrepancy time.