21
2110182-10-02/20 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-A-C5H-EX
EN
12. System status table
Operating mode
Actuator/door position
Safety outputs LA and LB
PLC
LED indicator
Output
State
Output
OUT (status signal)
ST
ATE (gr
een)
OUT/ERROR
(yellow)
OUT/ERROR (r
ed)
Normal operation
closed
on
1
Normal operation, door closed
open
off
0
Normal operation, door open
Teach-in operation
(only unicode)
open
off
0
4 Hz
Initial setup after delivery, ready for first teach-in operation
closed
off
0
1 Hz
(60 s)
Teach-in operation
closed
off
0
Positive acknowledgment of completion of teach-in operation.
To activate the actuator code from the teach-in operation in the evaluation
unit, the operating voltage must then be switched off at the evaluation unit for
min. 3 seconds.
Status indication
(only unicode)
X
off
0
3 x +
Indication after 1st to 5th teach-in operation
X
off
0
2 x +
Indication of the remaining teach-in operations after the 6th teach-in operation
X
off
0
1 x +
Indication of the remaining teach-in operations after the 7th teach-in operation
X
off
0
Device cannot perform any further teach-in operation
Fault display
X
off
0
Internal component failure or
excessively high interference (EMC) or short circuit/external power at the LA/
LB safety output
Operating fault
(only unicode)
closed
off
0
1 x
Incorrect 9th teach-in operation (unicode only)
closed
off
0
2 x
Incorrect teach-in operation for an old actuator (unicode only)
closed
off
0
3 x
Negative acknowledgment for teach-in operation. Actuator was held in front
of the read head for less than 60 s
Key to symbols
N
0 Volt or not connected
1
24 Volt
0
0 Volt
LED not illuminated
LED illuminated
15 Hz (8 s)
LED flashes for 8 seconds at 15 Hz
3 x +
LED flashes three times and then illuminates continuously
3 x
LED flashes three times, and this is then repeated
X
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the guard. If the fault is still dis-
played afterward, briefly interrupt the power supply. Contact the manufacturer if the fault could not be reset after restarting.
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.