![ETS 4431T Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/ets/4431t/4431t_operating-manual_2434443022.webp)
Model 4431T Shielded Bag Test System - Operating Manual
22
D00003 Rev. K.
IF
the system is in CONTINUOUS mode, the HV discharge will occur automatically and the red “HV
Pulse” indicator will flash at each discharge.
7.4.2 You will see the captured waveforms on the preview screen as they are acquired:
Figure 7-15 – Captured Test Waveform
IF
the system is in MONITORED mode, you will be asked to APPROVE or RE-DO each discharge.
IF
the system is in CONTINUOUS mode, the complete set of discharges will occur automatically for this
sample.
7.4.3 Based on the number of samples entered in the test profile, the previous 3 steps will be repeated
until all samples have been tested.
7.5 Test Data.
All test data is saved at C:\ETS\:
Each test sequence generates a Summary File named C:\ETS\ETS4431SUMMARYxxxx.txt containing
peak and energy totals. (“xxxx” is the test reference number.)
Each test sequence generates a Data File named C:\ETS\ETS4431-TESTxxxx.txt containing all
waveform data.
These are easily readable text files. Files can be easily identified and maintained by windows file name.
It is not recommended that any editing be done on these original files. They can be accessed at any
time by the ETS 4431-T Test Manager or other programs such as wordpad or excel for reports or
analysis.