3. Prepare the Ozone Modules
3.1 Set the device addresses
Each Ozone Module must be set to a unique device address.
Start by removing the bottom cover by unscrewing the four (4)
M5x12 bolts from the side panel with T4 screwdriver and keep
them in a secure place for later use.
To assign unique addresses to Ozone Module a narrow 2mm
flat screwdriver will be needed. All Ozone Modules connected
to a single Control Panel must have a unique device address.
Addresses need to be set in ascending order begin with Ozone
Module closest to the Control Panel and increasing by one for
each sequential module. The first connected Ozone Module
should have the address 1.
Example:
Ozone Module one (Adress 1):
Switch 1x = 1
Switch 10x = 0
Ozone Module thirteen (Adress 13):
Switch 1x = 3
Switch 10x = 1
Mark the installation positions of each Ozone Module
The location of each Ozone Module shall be marked by placing
an identification label on the upper front panel of the canopy. The
label should match the device address of the module installed
beneath it. You will find a sheet of labels in the Control Panel
package.
NOTE!
Installation may only be carried out byby specialist and authorized persons in accordance with
local, regional, national standards and regulations.