Etrel Load Guard | User manual
|
CONFIGURATION OF THE LOAD GUARD
To configure Load Guard, the following is needed:
•
IP address of the charging station that is used to connect Load
Guard to.
•
Serial number of the charging station that is used to connect Load
Guard to.
LOAD GUARD NETWORK SETTINGS
Click on the white part of the screen (the line with Load Guard data) opens
the configuration window.
Figure 27: Windows for configuration settings
Default IP address of the Load Guard is
192.168.1.249
.
If the measured data are presented in a same way as on the above figure
(currents, powers, voltages, times ...) it means that the Load Guard
Configurator software successfully connected to the Load Guard.
If the time on the Load Guard is wrong, the time synchronization must be
performed with the click on
Sync device time
, otherwise the connection
will not be functional. After that the settings are saved with a click on
Save
changes
(bottom right).
Charging station can be connected in LAN network in two ways, statically
or dynamically. If there is DHCP server present in the network, the
dynamic option can be selected in
Load Guard communication settings
.
Otherwise the
Static
option must be selected. Settings are displayed in
the following figure.