Valve guide
Caution
Before measuring the valve guide, clean carbon
deposits with reamer.
Tool: 5.0 mm valve guide reamer
Measure and record each valve guide inner
diameters.
Service limit: 5.03 mm
The difference that the inner diameter of valve
guide deducts the outer diameter of valve stem is
the clearance between the valve stem and valve
guide.
Service Limit: IN
→
0.08 mm
EX
→
0.10 mm
Caution
If clearance between valve stem and valve guide
exceeded service limit, check whether the new
clearance that only replaces new valve guide is
within service limit or not. If so, replace valve
guide.
Correct it with reamer after replacement.
If clearance still exceeds service limit after
replaced valve guide, replace valve stem too.
Caution
It has to correct valve seat when replacing valve
guide.
5.0 mm valve guide reamer