background image

1. Unscrew the fixed screws which hold the PCB cover in place.  Remove 
the PCB cover.

1. Unlock the 4 screws from the PCB cover and leave 
loose about 3mm.

1. Mount the 2 units of Bracket B to the back of the 
fixture with screws supplied.

2. Install the Lens / Refractor over the PCB – aim the bump rectangle in 
the middle of the lens / refractor to sit over the PCB boards wire entry 
(shaded area).  Please dispose of or store PC cover that came with fixture.  
It is not to be installed over the LENS / REFRACTOR.

2. Attach the Reflector to the fixture front and turn it 
clockwise to secure in place, using keyless slots.

2. Install Bracket A to Bracket B as per above images.

3. Tighten all screws ensuring the Reflector holes are 
locked in place.

3. Adjust the required angle of the bracket as per 
above images and tighten screws to lock.

3. Tighten all screws. Installation is finished.

4. Installation complete.

4. Installation complete.

Head Offi ce -

 1850 Wilson Ave. · Toronto, ON · M9M 1A1 · 

Tel:

 416.741.7336 · 

Fax:

 416.741.9104 

Toll free:

 in Canada. 1.800.661.9610 · in USA. 1.888.762.5384 (SOCKETS4U)

www.etlin-daniels.com· For sales/service questions - [email protected] 

SAVE THESE INSTRUCTIONS - READ ALL INSTRUCTIONS CAREFULLY

LENS / REFRACTOR INSTALLATION - 60 ˚ AND 90 ˚

ALUMINUM REFLECTOR / PC REFLECTOR INSTALLATION

YOKE MOUNT INSTALLATION

Bracket B

Screws

Bracket A

Bracket B

Bracket B

Nut

Nylon Gasket

Bracket A

 Stainless Steel Gasket

Nut

Nylon Gasket

R

INSTALLATION FOR HBRA7 SERIES ROUND WITH

 MICROWAVE SENSOR BASE HIGH BAY