REMOTE CONTROL APPLICATIONS

BUTTON NAME

DESCRIPTION

ON / OFF

1. “ON/OFF” key only functions as a switch of the light.

2. If this button is pressed to turn off the fixture before power is turned off, the fixture will 

remain off after power is turned on again.

MW / PIR

Change from the microwave sensor function to PIR sensor function, and the other around.

Scene

Press “Scene” button, products with DIP switch will be controlled by DIP switches; 

otherwise all the setting will be just initial, that is 100% detection range, hold time 5S, 

no standby time and daylight threshold disabled.

Start

Start - Press the button before choosing the parameters.

Memory

Memory - Press the button after choosing all the parameters to save them

Apply

Apply - Press the button to deliver the saved settings to the other sensors directly

Hold Time

The period of light keeping 100% brightness after moving objects leave the 

detection area.

Standby Period

The period of light keeping low output before it gets completely off. When it’s preset as --, 

the light always keep at low output even no movement in the detection area.

Power %

Press the button to change the output power from 0% to 100% it changes 5% every press.

Test (2s)

The button “Test (2s)” is for testing purpose after comissioning. Pressing this button, the 

sensor goes to test mode (hold time is only 2s)

Increase or decrease the parameters.

Daylight Threshold Definition of the ambient brightness; only when the ambient brightness is lower than the 

preset specific lux amount, the sensor will work,; when it’s preset as “disable”, the 

sensor works everytime it detects motion regardless of the ambient lux level.

Standby Dimming 

Level

The definition of low output during the standby period.

Detection Range

The area in which movement will trigger the sensor, 100% detection area also means 

strong sensitivity

MEMORY AND APPLY MODE.

1.  Press the On/Off Button to turn the fixture on or off.
2. To Reset the parameters, follow steps as below:
    • Press ON to turn on the fixture if it is off.
    • Press START at the fixture being set.
    • Press the buttons of DETECTION RANGE, HOLD TIME, STANDBY DIMMING LEVEL, STANDBY PERIOD, and DAYLIGHT 
       THRESHOLD one after the other in sequence. Press “+/-“ to set Parameters.Press MEMORY to memorize the settings.
NOTE: THE INTERVAL OF EACH PARAMETER SETTING SHALL BE CONTROLLED WITHIN 30 SECONDS
3. To program other fixtures in the array that will have the same program.
    • Press ON to the second fixture.
    • Press APPLY.

ISOLATED SETTING MODE.

1. Press the On/Off Button to turn the fixture on or off. Press SCENE – the remote will activate settings that were 
saved last or remain at factory settings.
2. To reset the parameters, follow the steps below:
    • Press ON to turn the fixture on, if it was off to start.
    • Press any button of SCENE, TEST , APPLY to begin the sensor detection mode.
    • PRESS the buttons of Detection Range, Hold Time, Standby Dimming Level, Standby Period and Daylight 
       Threshold one after the other in sequence.
NOTE: 
• Setting will be saved automatically and remain until you press RESET again.
• Fixture will flicker when you are setting each parameter.
• The Icon will flash when setting the corresponding parameter.

-

+