Page 28
USER MANUAL ref 9011509-01
AFO485 and RFO485
4.7. Range of modems on the CAN network
Taking into account the technology of the CAN network, only a point to
point transmission can be realised.
The range of the optical link is determined in two steps :
Step 1
: The length of the link can not exceed the values below, it is
related to the type of fibre optic and the optical source of the AFO485
adaptor.
Range on multimode fibre G50/125
Optical
Source
Optical
power*
Reserve
F.0.
attenuation
Min. range
DB
dB
dB/Km
Km
Product reference
A
B
C
D1 = (A-B) / C
AFO485-C10
820 nm
12
3
2,5
3,5
AFO485-C20
1300 nm
12
3
1
9
Range on multimode fibre G62.5/125
Optical
Source
Optical
power*
Reserve
F.0.
attenuation
Min. range
dB
dB
dB/Km
Km
Product reference
A
B
C
D1 = (A-B) / C
AFO485-C10
820 nm
15
3
3,5
3,5
AFO485-C20
1300 nm
15
3
1,5
8
Range on single mode fibre E10/125
Optical
Source
Optical
power*
Reserve
F.0.
attenuation
Min. range
dB
dB
dB/Km
Km
Product reference
A
B
C
D1 = (A-B) / C
AFO485-C30
1300 nm
17
3
0,5
28
AFO485-C40
1300 nm
10
3
0,5
14