CONTACTING CUSTOMER SERVICE

)RUDVVLVWDQFHFRQWDFW&XVWRPHU6HUYLFH2IƓFHKRXUVDUH

from 8:00 AM until 5:00 PM ET.

Email:

  [email protected]

Web:

   networketi.com

Mail:

   ETI

1850 North Sheridan Street

South Bend, IN 46628

RETURNS AND REPLACEMENT PART PURCHASES

Equipment cannot be returned for credit once it has 

been installed. ETI will repair or replace faulty equip-

ment under warranty. Prior to removal of equipment for 

warranty return, please contact ETI Technical Support for 

troubleshooting assistance.
Before returning a unit to ETI, obtain a Return Merchandise 

Authorization from our Customer Service Department, 

available between 8:00 a.m. and 5:00 p.m. Eastern Time. If 

possible, use the original container and packing materials 

when packing the unit for shipment. It is important to 

mark the Return Merchandise Authorization clearly 

on the outside of the shipping container so that it may 

be correctly processed upon receipt at Environmental 

Technology. For more information about replacement 

parts or for a replacement Data Sheet or Manual, please 

visit www.networketi.com.

LIMITED WARRANTY

ETI’s two year limited warranty covering defects in 

workmanship and materials applies. Contact Customer 

Service for complete warranty information.

DISCLAIMER

ETI makes no representations or warranties, either 

expressed or implied, with respect to the contents 

of this publication or the products that it describes, 

DQG VSHFLƓFDOO\ GLVFODLPV DQ\ LPSOLHG ZDUUDQWLHV RI

PHUFKDQWDELOLW\RUƓWQHVVIRUDQ\SDUWLFXODUSXUSRVH(7,

reserves the right to revise this publication, and to make 

changes and improvements to the products described 

in this publication, without the obligation of ETI to notify 

any person or organization of such revisions, changes or 

improvements.

Copyright © 2019 ETI,

®

 All rights reserved.

Heat Tracing Sales

Mt. Airy, MD

(410) 795-2223

www.heattracingsales.com

Heat Tracing Sales

Mt. Airy, MD

(410) 795-2223

www.heattracingsales.com

Содержание Tracon FPT-130

Страница 1: ...se with Inductive loads Inductive loads may create nuisance tripping of the Ground Fault Equipment Protection circuit Utilisation de charge r sistive uniquement Ce produit n est pas destin tre utilis...

Страница 2: ...s la terre doivent toujours tre utilis s pour r duire les risques de choc et d incendie et prot ger l quipement Le c blage lectrique des l ments chauffants doit tre install conform ment aux exigences...

Страница 3: ...round Fault Equipment Protection with manual and automatic test function Alarms for excess ground fault current low load current and temperature Alarms indicated with panel LED lights and relay contac...

Страница 4: ...he hub to the conduit system before connecting the hub to the enclosure The unit comes with two installed liquid tight cable JODQGV 2QH RI WKHVH WWLQJV LV IRU WKH WHPSHUDWXUH VHQVRU cable and the othe...

Страница 5: ...r provides dual Form A DPST contacts rated for heater loads up to 30 amps and 277 volts ac The dual contacts on the contactor are used to control both legs of the input power Line and Neutral Manual L...

Страница 6: ...the COM terminal If the system needs a contact to close to signal an alarm or power off condition connect the other alarm relay lead to the NC Normally Closed terminal See Figure 6 If the system need...

Страница 7: ...up If any DIP switch is changed while the unit is on then the power needs to be turned off and on again for the new setting to take effect FPT130 Thermistor Fault FPT130 Set Point GPT Heat On Fire Pro...

Страница 8: ...tpoints except the 30 F 1 1 C setpoint For the 30 F 1 1 C setpoint the LOW TEMP alarm will indicate when the temperature drops to 28 F 2 2 C Blinking indicates sensor fault Blinking fast indicates Hig...

Страница 9: ...KH EXWWRQ DW this point The unit will exit Manual Mode Note 7KH EOXH PD DVK IRU D FRXSOH RI VHFRQGV after releasing the red TEST RESET pushbutton The blue LED will indicate whether the LOW TEMP Alarm...

Страница 10: ...e setpoint Low current alarm delay 5 s Ground fault limit current 30 mA Self Test Interval 24 h User Interfaces Pushbuttons Test Reset DIP switches Temperature setpoint Thermistor fault mode Fire prot...

Страница 11: ...ion clearly on the outside of the shipping container so that it may be correctly processed upon receipt at Environmental Technology For more information about replacement parts or for a replacement Da...

Отзывы: