19
8• MAINTENANCE
8•2•1 HYDROSTATIC UNIT OIL CHANGE
OR REFILL
• Stop the engine for oil change or checks.
• Park the machine on a fl at and horizontal area.
LEVEL CHECK
• Check the oil level when the system is cold, by looking at the tank
marked [UP] - [LOW] at the rear of the machine (see picture 8 page 10).
• First oil change : after 15 hours
• Next changes : every 100 hours or once a year
• Recommended oil : HV 46 (ref. : 29592 - 2 liters)
• Capacity : 0.5 l
• To drain the oil, unscrew and remove the drain plug (see a picture 9
page 11). Let the oil fl ow and screw the drain plug again.
WARNING !
Don’t let fl ow all the oil!
TO COMPLETE THE OIL LEVEL
• Fill the hydrostatic unit by the tank.
• Spill slowly the oil in order that no air is catched in the unit which
could make the restart harder.
• If in spite of this recommendation there is some air in the unit
unscrew the venting plug (see b and c picture 10 page 11). As soon
as some oil fl ows through it :
- Stop the venting plug.
- Refi ll until the level is slighty under the tank upper level mark.
WARNING !
Only use HV 46 quality oil to refi ll the
hydrostatic tank (ref. : 29592 - 2 liters). We recommend to use
an ETESIA fi lter unit fi tted with a 25 µm fi lter (ref. : 29977).
WARNING !
Drive the machine (forward - reverse) and
check the level. The level has to be between the [UP] and
[LOW] marks. If necessary, to up.
• Dispose used oil in an approved collection point.
8•2•2 TRANSMISSION GEARBOX OIL
CHANGE OR REFILL
• Stop the engine for oil change or checks.
• Place the machine on a fl at and horizontal area.
• Check the oil level when the system is cold. The level should reach
the lower limit of the gauge and can be checked by unscrewing the
gauge (see picture 11 page 11).
• First oil change : after 15 hours
• Subsequent changes : every 100 hours or once a year
• Recommended oil : HD 220 (ref. : 29590 - 1 liter)
• Capacity : 1 l
• To change gearbox oil, unscrew the drain plug (see picture 12 page
11). Let the oil fl ow and tight the drain plug.
• To refi ll, unscrew the oil level gauge (see picture 11 page 11) and
fi ll with oil through this opening.
WARNING !
When the machine is on a fl at horizontal
surface, the level shoud not exceed the lower limit of the gauge.
• Dispose used oil at an approved collection point.
8•3 MAINTENANCE OF THE
TRANSMISSION AV98X
(SEE HST OIL
REPLACEMENT PAGE 14 AND 15)
8•4 MAINTENANCE OF THE
BATTERY
8•4•1 MAINTENANCE OF THE 12 V BATTERY
• The 12 V battery is located under the front cover.
• This lead-acid battery requires very little maintenance.
• The level of the electrolyte should be checked every 50 hours, and
should always lie between the upper [Max] and lower [Min] level
markers. The level of the electrolyte in the cells can be checked
without removing the battery, by opening the front cover.
• If the electrolyte level of a loaded battery is close to the [minimum]
marker, add distilled water up to the level of the [maximum]
marker. Never overfi ll the battery or add acid.
• Check that the battery terminals are not oxidized.
• If necessary, clean the terminals and coat with special battery
grease.
WARNING!
If, for any reason, it is necessary to
disconnect the battery, always disconnect the negative
terminal fi rst, followed by the positive terminal.
• In case of overfi lling of the battery when topping up, rinse the
affected areas thoroughly to prevent corrosion.
8•4•2 CHARGING THE BATTERY
WARNING!
Remove the battery from the ride-on brush
cutter by disconnecting fi rst the negative terminal and then
the positive terminal.
• Check the electrolyte level. If necessary, top up with distilled water.
• Wear the individual protection equipments that are necessary
while making the maintenance of the battery (safety glasses and
gloves…).
• Connect the battery to the charger.
- Charge voltage : 12 V
- Charging current : max. 3 A for AV98, 16 A for AV95
- Charge time : up to 12 hours, according to need.
Lead-acid batteries emit explosive gas mixtures during
charging. Avoid naked fl ames and sparks and do not smoke.
The battery should always be charged in a well-ventilated
area. The battery contains sulphuric acid which is highly
dangerous and liable to cause serious injury upon contact
with the skin.
• Extreme care should therefore always be taken.
WARNING!
In case of contact with the skin or eyes,
rinse thoroughly with clear water. Seek medical attention
immediately when necessary. Always keep the battery and
acid out of the reach of children.
WARNING!
Measures taken for the application of
Directive 91/157/CEE relating to the marketing of batteries
and accumulators containing certain hazardous materials
and their elimination.
ELIMINATION OF BATTERIES
Batteries contain hazardous materials and must under no
circumstances be disposed off into the environment. They are the
subject of specifi c rules governing their elimination.
You can return your used ETESIA batteries to your Approved Dealer
free of charge, and he will take care of their elimination ; or you can
give them to an organisation that deals specifi cally with waste or take
them to a special battery collection point.
WARNING!
Batteries kept in a discharged state cannot
subsequently be recharged and are not covered under the
terms of the warranty.
Содержание AV95
Страница 6: ...1 1 2 3 4 6 Rectangle A Rectangle B 2 KEY TO DIAGRAMS SAFETY RectangleC Rectangle D...
Страница 10: ...5 4 3 b a 7 6 8 10 4 PICTURES...
Страница 12: ...18 16 17 b A 19 20 21 a a 12 4 PICTURES...
Страница 25: ......
Страница 27: ...ETESIA SERVICE GARANTIE 13 rue de l Industrie 67165 WISSEMBOURG CEDEX France Stamp here please...