Floor Mounting
GU145(S) / GU195(S,M) can be installed standing on combustible floor surface, or on a water heater stand.
Be sure to use a suitable draining pan under the unit if leakage of the tank or connections will resuit in damage to
the area adjacent to the appliance.
Place unit directly on an even surface. Factory installed rubber feet can be adjusted if the surface is slightly uneven.
Secure the unit to the wall with included wall mount bracket. Be sure to install the wall mount bracket to the wall studs.
Per ANSI / NSF-5, floor standing directly on the hard surface is NOT an acceptable installation method. The unit
must be elevated at least 6" off the floor. This mounting clearance provides access for clearing any possible debris
or accumulated water seepage that can occur below the unit. Install the unit on Eternal Water Heater Stand (P/N
314080136) that raises the unit at least 6" above the floor.
□
□
Standing Installation
Floor Standing
Earthquake Proo
ng
Water Heater Stand For Commercial Food Service
6" min
Factory Installed Rubber Feet
If local codes require the water heater to be raised 18" above
oor, installing GU145(S) / GU195(S,M) on the
optional Eternal Water Heater Stand (P/N 314080136) will satisfy code. In conjunction, the unit on stand raises
the FVIR compliant igniter and burner at least 18" off the
oor. Alternatively, raising the unit at least 6" off the
oor
will also satisfy code.
CAUTION
!
!
Philips Head Screws
M8x15x4pcs
Содержание GU145 (S)
Страница 5: ...5 Dimensions GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M ...
Страница 6: ...6 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M ...
Страница 7: ...7 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S ...
Страница 50: ...50 DIAGNOSTICS Before calling for service review the following diagnostic steps rst for saving time and money ...
Страница 56: ...56 Wiring and Connection Diagram Wiring Diagram MODEL GU195 M 508 11 12 21 22 1195 M ...