READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product contains glass, care must be taken when 

assembling, fitting or handling to prevent personal 

injury or damage to the product.

This light fitting must be installed by a competent 

person in accordance with the Building Regulations 

making reference to the current edition of the 

IEE Wiring Regulations (BS7671). The Building 

Regulations may be obtained from HMSO or viewed 

and downloaded from www.communities.gov.uk 

following the link for Building Regulations.

As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.

The lamps (bulbs/tubes) supplied with this fitting are 

consumable parts and therefore may be outside of 

any warranty offered.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse.

When working at heights, please use a suitable 

platform. 

Disconnect the fitting from the electrical supply 

before flash or high voltage testing.

Suitable for outdoor use.

This product is suitable for installation on surfaces 

with normal flammability e.g. wood, plasterboard, 

and masonry.  It is not suitable for use on highly 

flammable surfaces (e.g. polystyrene, textiles). 

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

The chosen location of your new fitting should allow 

for the product to be securely mounted and safely 

connected to the mains supply (lighting circuit).

When choosing the location for your new fitting, 

ensure that the fixings will be anchored in a solid 

surface e.g. concrete, brick or a joist—do not fix 

directly onto panelling, cladding, plasterboard etc.

If the location of your new fitting requires the 

provision of a new electrical supply, the supply 

must conform with the requirements of the Building 

Regulations making reference to the current edition 

of the IEE Wiring Regulations (BS7671).

This product is designed for permanent connection 

to fixed wiring: this should be either a suitable 

lighting circuit (protected with a 5 or 6 Amp MCB or 

fuse) or a fused spur (with a 3 Amp fuse) via a fused 

connection unit.

We recommend that the supply incorporates a 

switch for ease of operation.

Make connections to the electrical supply in 

accordance with the following code:

Live - Brown or Red 

Neutral - Blue or Black 

Earth - Green and Yellow

When making connections, ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened 

onto the bared conductors and not onto any 

insulation.

This product must be connected to Earth.

ImPORTANT:

 Always switch off at the mains before 

changing the lamp.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out: 

these tests are specified in the Wiring Regulations 

(BS7671) referred to in the Building Regulations

 

CLEANINg:

Disconnect the power and clean the exterior only of 

this fitting with a moist (not wet) cloth.

Do not use any chemical or abrasive cleaners.

 

EvENTUALLy, yOU mAy WANT TO 

REPLACE THIS PRODUCT:

Regulations require the recycling of Waste from 

Electrical and Electronic Equipment (European 

“WEEE Directive” effective August 2005—UK 

WEEE Regulations effective 2nd January 2007). 

Environment Agency Registered Producer: WEE/

GA0248QZ. 

WHEN YOUR PRODUCT COMES TO THE END OF 

ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE 

RECYCLE IT WHERE FACILITIES ExIST - DO NOT 

DISPOSE WITH HOUSEHOLD WASTE.

 

IF yOU ExPERIENCE PROBLEmS:

If you believe your product is defective, please return 

it to the place where you bought it. Our Technical 

Team will gladly advise on any Eterna Lighting 

product, but may not be able to give specific 

instructions regarding individual installations.

For breakage information visit:  

www.eterna-lighting.co.uk

INSTALLATION:

01.  Choose the location for your new floodlight 

giving consideration to the points above.

02.  Remove the bracket from the light by removing 

the screws and nuts on each side.

03.  Fix the bracket to the mounting surface using a 

spirit level (if available) to ensure that the bracket 

is fixed level and using appropriate fixings (not 

supplied).

04.  Attach the light fitting to the bracket using the 

screws, washers and nuts you removed earlier.

05.  Rotate the fitting in the bracket so that the light 

faces directly downwards, this will give you easy 

access to the connection box from above.

06.  Remove the cover from the connection box by 

removing the four screws and lifting off.

07.  Remove the gland nut from the side of the 

connection box and thread your supply cable 

through.

08.  Remove the rubber gland from the cable entry on 

the side of the connection box and thread onto 

the cable.

09.  Thread the supply cable into the connection box 

and make the connections according to the 

colour code listed opposite and observing the 

terminal identification markings inside the 

connection box.

10.  Push the rubber gland and nut back along the 

cable until they locate in the threaded cable entry 

and tighten the nut sufficiently to grip the cable 

and make the entry water-tight.  

Do not over-tighten.

11.  Replace the connection box cover and replace the 

four screws. Ensure that the sealing gasket is 

correctly positioned.

12.  Adjust the position of the light so that it 

illuminates the desired area and limiting the 

spread of light onto neighbouring property.

13.  Tighten the bracket fixing screws on the side of 

the fitting to lock in position.

14.  Undo the screw at the top of the glass safety 

shield on the front of the light fitting and allow to 

hang from the hinge.

15.  Carefully remove the lamp from the box taking 

care not to touch it with bare hands.

16.  Using a soft, dry, clean cloth, grip the lamp 

and fit it between the sprung contacts in the 

lampholder.

17.  Close the glass safety shield and tighten the 

screw. Ensure that the waterproofing gasket in 

correctly positioned.

18. Restore the power and switch on.

SPECIFICATION:

 

 

Weatherproof:  IP44 

Class 1 Protection:  Class 1 / Earthed

 

LAmP REPLACEmENT:

01. Switch off the electricity at the mains.

02.  Allow to cool down then undo the screw at the 

top of the glass safety shield and allow to hang 

down on the hinge.

03.  Remove and replace lamp making sure it is of 

the same type and wattage as stated on the re 

lamping label, do not touch with bare fingers, 

grip the lamp with a tissue or clean soft cloth.

04.  Replace the glass safety shield and tighten 

the retaining screw. Ensure that the gasket is 

positioned correctly.

05. Restore the power and switch on.

 

REPLACEmENT LAmP TyPE:

ETH120L / ETH120LWH:

 requires 120W R7s linear 

halogen (Eterna code: LH120).

ETH400L / ETH400LWH:

 requires 400W R7s linear 

halogen (Eterna code: LH400).