15
4. (
Optional
) To switch to AC current
measurement, press
SEL/REL
once.
5. Carefully break the current path to be
tested.
6. Connect the
red test lead
to the positive
side of the break, and the
black test lead
to the negative side of the break.
7. Turn on the circuit power. The measured
value will show on the LCD.
1.
Turn off power to the circuit and discharge
all high-voltage capacitors.
2. Insert the
black test lead
into the
COM
terminal. If you are measuring microamps
(
μ
A) or milliamps (mA), insert the
red test
lead
into the
terminal. If you are
measuring Amps (A), insert the
red test
lead
into the
10A
terminal.
3. Set the rotary dial to the correct current
measurement range.
Note:
If you are unsure of the range of
the current you are measuring, select the
highest range (A) first (inserting the
red
test lead
into the
10A
terminal), then
use the lower ranges to find an accurate
measurement.
Note:
If the display only reads “
0.0
” when
measuring current using the
Terminal, it means that the 200mA fuse
must be replaced.