18
Source 4WRD II Installation and User Manual
Troubleshoot the Source 4WRD II
The following error codes may be seen on the Source 4WRD II user
interface. For more troubleshooting assistance, see
•
OtP
(OTP) indicates that the fixture has gone into over-temperature
protection. Allow the fixture to cool, and then reset the fixture to
clear the code.
-
For DMX mode: Return the DMX control to 0.
-
For AC mode: Remove the fixture from power for five seconds
and then restore power.
•
UtP
(UTP) indicates that the fixture has gone into under-
temperature protection. Allow the fixture to warm to a minimum of
5°C (41°F).
•
Flashing DMX address indicates loss of DMX.
•
Dark screen indicates loss of power or fixture time-out. In the event
of time-out, press any button to wake the user interface. If this fails
to wake the user interface, troubleshoot the power loss:
-
Verify that all cables are fully seated and that power is applied to
the fixture.
-
If a working Source 4WRD II LED is available, exchange the Source
4WRD II LED with the working Source 4WRD II LED to further
isolate any issues.
-
If the fixture still does not respond, contact ETC Technical
Services for additional troubleshooting steps or to arrange a
repair. See
Help from ETC Technical Services on page 2
for
contact information.