Source 4WRD II Installation and User Manual
11
Connect Cables
You can control the fixture using AC power or DMX. Configure the fixture
to use the appropriate control method on the user interface. See
Configure the Fixture on page 14
.
WARNING:
Do not use or store the Source 4WRD II fixture
below 5°C (41°F). When the fixture has been stored or
transported in cold temperatures, allow it to warm to room
temperature for a minimum of 1 hour before applying power.
Applying power to a cold fixture will cause damage to the
fixture and void ETC warranty.
Note:
For optimum performance, make sure that your dimmer is
out of regulated mode. See
for
recommended dimmer settings.
Note:
Connecting both power and data from a SmartBar 1 to a
Source 4WRD II fixture may cause flickering.
1. If you are using DMX control: Connect one RJ45 data cable for
data-in and one for data-thru, as needed. Use the strain relief at
the bottom of the fixture to support the data cables. Leave a loop
of data cable between the connector and the strain relief to ensure
that the connection point is not stressed.
•
To order an RJ45-to-female XLR adapter, use ETC part number
W6538.
•
To order an RJ45-to-male XLR adapter, use ETC part number
W6539.
2. If you are using DMX control and this is the last fixture in the line,
terminate the fixture with a 120 Ohm resistor. Please contact your
ETC customer service representative to purchase ETC part number
N4086. See
Help from ETC Technical Services on page 2
3. Connect the fixture to the power source.