16
CEM3 Sensor Rack Retrofit Manual
Verify the Retrofit
1:
Put the dimmer modules back in the enclosure in the correct/original order, making sure all
dimmer circuit breakers in the enclosure are turned “Off.”
2:
Put the CEM3 in the enclosure in Test Mode (enabled using the switch located on the right hand
side of the PCB).
3:
Power up the enclosure.
4:
Check that the CEM3 powers up and the enclosure fan turns on.
5:
Check that the signal lights on all dimmers are illuminated. If not, power down the enclosure and
verify CEM3 and all ribbon cables are fully and correctly seated.
Configure the CEM3
1:
Change CEM3 from Test Mode to Normal Mode (enabled using the switch located on the right
hand side of the PCB).
2:
Configure the enclosure to reflect the dimmer module types installed. Verify that the enclosure
type is correct. (CEM3 should have determined this from the DIP switch settings. See
). Use the front face panel interface to configure the CEM3. See the
CEM3
Quick Guide
that ships with the CEM3 for more information.
3:
Configure the data types that will be used (DMX and sACN) including the enclosure patch.
4:
Program and verify Panic (if used).
5:
After the dimmer ribbon cables are connected in the correct order, set one dimmer from each
group of twelve slots on at a time, and then verify the correct dimmer signal light as it illuminates.
6:
Verify all sources of control (DMX, sACN, Panic, Preset stations) function correctly.
7:
Turn all dimmer circuit breakers back on.
Final Steps
1:
Collect and properly dispose of all debris created during the upgrade process.
2:
For future service needs, it is recommended that you send copies of the final CEM3 configuration
files for each enclosure to ETC technical services (
). Include your
job number and the date the configuration was adjusted.
Note:
If AF cards are present, it may take some time for them to fully load their software.
Note:
PCBs (such as the backplane termination board, beacon board, and AF cards) may be
deemed hazardous e-waste by some municipalities. Please dispose of in accordance
with local requirements.
Note:
Send CEM3 configuration files saved out of the Sensor3 enclosure, not configuration
exported from ETC Net 3 Concert (if used).
Содержание Sensor3
Страница 19: ...The Retrofit 17...