6
W1 Installation Manual
W1 Models
Variant
Load Type
Output Type
Output
Voltage
Per
Circuit
Limits
Driver
Limits
Output
Connectors
W1 Fade to Warm
Driver
FDW1FTWD (-CE)
up to four total
ETC ArcSystem Navis
100 Fade to Warm
luminaires
constant
current,
maximum
450 mA per
channel
48 VDC
450 mA,
21.6 W
1.8 A,
86 W
RJ45 and 4
two-pin
terminal
blocks
W1 Fade to Warm
Emergency Driver
FDW1EFTWD (-
CE)
W1 CC Driver
FDW1CCD (-CE)
•
up to four total ETC
ArcSystem Navis 100
Fixed White
luminaires
•
up to four total
ETC ArcSystem Pro
One-Cell White or
Fade to Warm
luminaires
-
Pro One-Cell
-
Pro One-Cell Small
-
Pro One-Cell Micro
•
200–700 mA fixtures
manufactured by
others
constant
current,
adjustable from
200–700 mA,
default output
600 mA (see
Configure the
W1 CC Driver
on page 22
48 VDC
700 mA,
33 W
2.8 A,
134 W
RJ45 and 4
two-pin
terminal
blocks
W1 CC Emergency
Driver
FDW1ECCD (-CE)
W1 CV Driver
Constant Voltage
FDW1CVD (-CE)
multiple 24 VDC fixtures 24 VDC
24 VDC
2.1 A,
50 W
6.25 A,
150 W
4 two-pin
terminal
blocks
W1 CV Emergency
Driver Constant
Voltage
FDW1ECVD (-CE)
W1 Chroma Driver
FDW1CHD (-CE)
up to four total
ETC ArcSystem Navis
100 RGBW luminaires
48 VDC power
and data
48 VDC
2.1 A,
100 W
RJ45
Note:
Use ONE type of output connector. For example, use the RJ45 receptacle OR
the two-pin terminal blocks on a W1 Fade to Warm Driver or a W1 CC Driver.
Note:
F-Drive W1 Drivers do not support ArcSystem Pro One-Cell High Output
luminaires.