Bridge Output Channels
43
Output Channels Bridged in Pairs
Bridging pairs of output channels can be done as shown below for control on output channel 1
and output channel 2, or on any pair of output channels as long as the output channels that are
electrically connected (bridged) have the same switch block settings. The illustrations and table
below show output channel 1 and output channel 2 bridged to form bridged output channel 1
and output channel 3 and output channel 4 bridged to form bridged output channel 3.
Detail of output channels bridged in pairs.
PWR
+
-
+
-
+
-
+
-
+
-
CONN4
CONN5
CONN6
CONN8
CONN9
CH1
CH2
CH3
CH4
ArcLamp Driver 150
Wall-Mount ArcLamp Driver 350/
Wall-Mount ArcLamp Driver 700
Rack-Mount ArcLamp Driver 350/
Rack-Mount ArcLamp Driver 700
ArcLamp Driver 150 Switch Settings for Output Channels Bridged in Pairs
Switch Block
(Output)
Switch Positions
1
2
3
4
5
6
S1 (LED OUT 1)
Do not adjust from
factory setting
ON
OFF
OFF
OFF
Do not adjust from
factory setting
S2 (LED OUT 2)
ON
OFF
OFF
OFF
S3 (LED OUT 3)
OFF
OFF
ON
OFF
S4 (LED OUT 4)
OFF
OFF
ON
OFF
ArcLamp Driver 350 and 700 Switch Settings for Output Channels Bridged in Pairs
Switch Block
(Output)
Switch Positions
1
2
3
4
5
6
S4 (CH 1)
Do not adjust from
factory setting
ON
OFF
OFF
OFF
Do not adjust from
factory setting
S3 (CH 2)
ON
OFF
OFF
OFF
S2 (CH 3)
OFF
OFF
ON
OFF
S1 (CH 4)
OFF
OFF
ON
OFF