Bridge Output Channels
41
Switch Functions
There are six switches on each switch block.
•
Switch positions 1 and 6 are factory set and should not be adjusted.
•
Switch positions 2 through 5 are factory set to allow each output to be controlled
individually. You must adjust these switches on the switch block that controls each output
channel that you want to bridge.
ArcLamp Driver 150 Factory Settings for Individual Output Channel Control
Switch Block
(Output)
Switch Positions
1
2
3
4
5
6
S1 (LED OUT 1)
Do not adjust from
factory setting
ON
OFF
OFF
OFF
Do not adjust from
factory setting
S2 (LED OUT 2)
OFF
ON
OFF
OFF
S3 (LED OUT 3)
OFF
OFF
ON
OFF
S4 (LED OUT 4)
OFF
OFF
OFF
ON
ArcLamp Driver 350 and 700 Factory Settings for Individual Output Channel Control
Switch Block
(Output)
Switch Positions
1
2
3
4
5
6
S4 (CH 1)
Do not adjust from
factory setting
ON
OFF
OFF
OFF
Do not adjust from
factory setting
S3 (CH 2)
OFF
ON
OFF
OFF
S2 (CH 3)
OFF
OFF
ON
OFF
S1 (CH 4)
OFF
OFF
OFF
ON
Setting Switches 2 Through 5 for Bridged Output Channels
Note:
Each output channel that you want to bridge must have the same setting for
switch positions 2–5 as the other output channels in the bridge. Output channels that
are electrically connected (bridged) with different switch settings may have reduced
capcacity.
Note:
If you are using a wireless ArcLamp Driver with ArcMesh, you must also set
bridged outputs to the same DMX address in the ArcSystem Configuration Software so
that they function as one output channel.
All output channels with the same settings on switch positions 2–5 will respond to the same
DMX address even if they are not electrically connected (bridged).