16
ColorSource ThruPower User Manual
Emergency
The Emergency menu option allows you to configure the ColorSource ThruPower’s
emergency contact input. When an active emergency contact is received, all non-emergency
dimmers in the cabinet are forced off, while all user-selected emergency dimmers are driven
to full.
When an emergency contact input is active, the LCD displays a message advising “Emergency
Active,” and the menu locks out all access to the system. After normal power is restored, the
cabinet resumes normal operation.
Activate the emergency contact input as follows:
Step 1:
After selecting the dimmers, scroll to the Emergency menu option and then press
the
[Enter]
(
) button.
Step 2:
Use the
[Increase]
(+) or
[Decrease]
(–) button to scroll between "Yes" or
"No", and then press the
[Enter]
(
) button.
Threshold
The Threshold menu option allows you to set the percentage level at which the relay switches
on, within a range of 1-99% when the circuit is in relay mode. The default value is 1%.
General Settings
The General Settings menu is used to configure standard features of your ColorSource
ThruPower dimmer pack.
BackLight
To configure the LCD backlight:
Step 1:
From the General Settings menu navigate to Backlight.
Step 2:
Press the
[Enter]
(
) button.
Step 3:
Use the
[Increase]
(+) or
[Decrease]
(–) button to set the backlight mode:
• Auto – LCD dims when not in use for a period of time
• Off – Always off
• On – Always on
Step 4:
Press the
[Enter]
(
) button.
General Settings
Backlight Auto
Language English
Restore Defaults
Содержание 7121A1212
Страница 28: ...24 ColorSource ThruPower User Manual...