3.5
Power Supply
The power supply of the ES582.1 module is connected via the USB 2.0 port of
a PC or a drive recorder. An external power supply is not required for the mod
-
ule. Notes about the requirements for the USB port of the PC are located in
chapter 6.6.1 on page 29.
3.6
Display of Operating State
Fig. 3
-
3
ES582.1 LEDs
The ES582.1 is equipped with five LEDs to display the operating state of the
module as well as the function of both CAN interfaces CAN1 and CAN2 (see
Fig. 3
LED
Display
Description
CAN1
Flashing yel
-
low
Communication at the CAN1 interface
Off
Communication at the CAN1 interface inter
-
rupted
Red
Communication error at the CAN1 interface
BUSY
Blue
Module is in the boot phase or a firmware
update is being performed. Do not discon
-
nect the module from the PC!
Off
Normal operation
ON
Green
Module is switched on
Off
Module is switched off
ER
Red
Booting was not successful or software error
of module.
Restart the module.
Off
No error
CAN2
Flashing yel
-
low
Communication at the CAN2 interface
Off
Communication at the CAN2 interface inter
-
rupted
Red
Communication error at the CAN2 interface