ETAS
Interfaces
AC Voltage Distributor ES4700.1-B
27
F11 for +12V DC
Fuse rating: see table “Tab. 9 1 Fuses”
F12 for -12V DC
Fuse rating: see table “Tab. 9 1 Fuses”
F13 for +5V DC
Fuse rating: see table “Tab. 9 1 Fuses”
The fuses are located on the back side of ES4700.1-B.
8.3.1
Pin assignment X8 Connector
Fig. 8-3
Connector "X8-Connector"
The pin assignment is as follows:
Pin
Signal
type
Imax
Signal_Name
Voltage
Range
1
n.c
--
--
--
2
GND
--
5V GND
GND
3
Output
6.5 A
+5V
5V +/- 10%
4
Output
3 A
-12V
-12V +/- 10%
5
GND
--
12V GND
GND
6
Output
3 A
+12V
+12V +/- 10%
7
GND
--
48V GND
GND
8
Output
2 A
+48V
48V +/- 10%
Tab. 8-3
Pin assignment of connector "X8"
8.3.2
Required male connector
Manufacturer: Harting
DSUB MA 8W8 SHELL W/O CONTACTS
Article Number: 09 69 410 0088
D SUB MIXED MA 10A PL3 sold.pow.contact
Article Number:
09 69 281 7420
8.3.3
Requirements for insulation of external circuits
Double or reinforced isolation required to hazard life circuits.