This chapter includes the technical data of the ES4700.1-B.
Mechanical Data
Height
3RU
Width
19“
Length
48.5 cm
Weight
10.5 kg
Security class housing
IP20 (IEC 60529)
Safety class
I (IEC 61140)
Tab. 4-1
Technical data
Electrical power supply
Voltage
3 phases 208 - 400 VAC
Frequency
50 - 60 Hz
Fuse of power socket
16 A
Internal power consumption
40 Watt (DC output voltages on X8 are
not considered)
Tab. 4-2
Electrical power supply
User accessible DC power supplies
(X8 connector)
Output voltage 48V
48V/ 2A
Output voltage 12V
12V/ 3A
Output voltage -12V
-12V/ 3A
Output voltage 5V
5V/ 6,5A
Tab. 4-3
User accessible DC power supplies
Socket-outlets
PROTECTED POWER L1 socket-outlet
See chapter 8.2
PROTECTED POWER L2 socket-outlet
See chapter 8.2
PROTECTED POWER L3 socket-outlet
See chapter 8.2
ONLY SERVICE socket-outlet
See chapter 8.5
Tab. 4-4
Socket-Outlets
Environment Data
Environment
Usage only in closed and dry rooms.
degree of contamination
2
Operation ambient temperature
5 °C - 40 °C (41 °F - 104 °F)
Storage temperature
-20 °C - +65 °C (-4 °F - 149 °F)
Relative air humidity
0 to 95% (noncondensing)
Altitude
max. 2000 m / 6500 ft