Safety Instructions
ETAS
12
AC Voltage Distributor ES4700.1-B
The cable shall be built by electrically skilled person. Before connecting the
cable to the POWER IN connector the connector pin assignment has to be
checked against the POWER IN connector pin assignment (see chapter 8.1)
Do not connect faulty cables. Remove damaged cables that are already in
use from operation immediately.
The cable has to be fixed at the rack system using cable clamps or zip ties. The cable shall
go through the rack system without any tap.
The cable has to be connected to main connection supporting protective earth (PE) and
separate neutral line (N)
WARNING!
Risk of electrical shock!
If protective earth are not connected, this may result in live housing parts
that may cause serious injuries or death.
Connect the ES4700.1-B only to a main connection with a correctly
connected protective earth (PE) an neutral line (N)
2.4.2
Operation
CAUTION!
Before using the ES4700.1-B the first time in a rack system, the wiring of it
has to be approved by an electrically skilled person.
Connection of high power consuming appliance
WARNING!
The maximum current of 16A in the supply line may not be exceeded, due
to the connected devices on the BATTERY connector, SERVICE socket-
outlet, PROTECTED POWER L1—L3 socket-outlet and X8 DC connector.
If not, the protection is not guaranteed
Usage of lead fuses
CAUTION!
Only lead fuses with their defined characteristic (Chapter 9) shall be used.
If not, the protection is not guaranteed.
Check the lead fuse characteristic of the used fuse, before using it.