Technical Data
ETAS
8.7
Electrical Data
8.7.1
Voltage Supply
8.7.2
Host Interface
8.7.3
Sensor Power Supply
Operating voltage
10 V to 33 V DC
Power consumption
ES313.1
max. 1.5 A
ES314.1
max. 2 A
Connection
LEMO
Bus
CAN 2.0B
Data transmission (baud rate)
500 kBd
Measuring data in the CAN message
Resolution (format)
Sign
8 bit (byte) and 16 bit (word), select-
able
signed, unsigned
Sensor power supply channels
4, separate for each input channel
Output voltage
Each channel can be set separately:
“Off”, in increments (2.5 / 5 / 7.5 / 10 /
12.5 / 15 V)
Output current
max. 60 mA
Protection
Short circuit-proof, overcurrent safety
switch-off,
Switch-off time = 400 ms
Switch-on time = 2000 ms
Diagnostics
In case of overcurrent, -FS is returned
as measured value