26
GB
/ 44
Emptying the dust container
Tip out the lid
A1
of the cleaner by pressing closure
A2
(pic. 15). Remove container
B
in
a manner described above. Place the container above a dustbin and press
B2
button, the
lid
B3
will tip out and dump the dirt into common house waste (pic. 17). Tip the bottom
back up in a way that it is properly secured and place the container back in the cleaner
and secure. We recommend emptying out the container outside of living area for hygiene
reasons.
Cleaning the dust container of the foam and HEPA filter
After approx. 5 emptying of the container we recommend to carry out a complete cleaning
of the system from settled dust. Remove the individual parts in the following manner:
–
Separator
B6
: press the
B2
button which will tip out the bottom
B3
. You can release the
separator by turning it in the direction of “open” and then pulling it out (pic. 19).
–
HEPA filter
B5
: can be released from the container by pressing the arrest latch and
pulling the filter out of the container (pic. 18).
–
Foam filter
B4
: pull out of the container (pic. 18).
Clean all accessories (i.e. container, separator, foam filter, HEPA filter) in lukewarm running
water with a cloth or a fine brush and let dry thoroughly (pic. 23). When all the parts have
dried, assemble them back.
Replacing the dust filter
Tip out the lid
A1
of the cleaner by pressing closure
A2
(pic. 15). Tip out the arrest closure
A10
and slide out the dust filter
D
(pic. 20) and dispose it with common house waste. Slide
the front part of the dust filter (direction of arrow) in the three ribs in the suction space of
the vacuum cleaner and then tip out the arrest closure and press the front all the way to the
seal. Now secure the front part with closure
A10
. Press to close the lid of the cleaner.
N
ote
Make sure that the bearing area and sealing elements are functional.
Replacing the micro filters
After replacing approx. 5 pcs of dust filters it is necessary to clean the micro filters or
replace them by new ones in case of visible damage. Dispose of used dust filters and
micro filters with common house waste. We recommend to replace the exhaust HEPA
micro filter at least once a year (according to amount of dirt).
Suction micro filter
Pull out the cassette
E
with micro filter in the suction space (pic. 22). Open the cassette,
clean the
E1
micro filter in running lukewarm water and let dry thoroughly (pic. 23). After
drying, insert the micro filter back into the cassette, close it, put it back behind the two
protrusions and slide it all the way into the suction space of the vacuum cleaner.
Ex
haust HEPA micro filter
Remove the cover of the vacuum cleaner by pulling by the two protrusions in the bottom
part of the exhaust cover
A11
(pic. 21). Pull out the cassette
A12
Clean the micro filter in
running lukewarm water (approx. 40 °C), e.g. with cloth or fine brush and let dry thoroughly
(pic. 23). When all the parts have dried, assemble them back.
ATTENTION
–
Do not use any abrasive cleaning agents or hot water to clean the HEPA micro filter or
foam filter.
–
Cleaning of the filter will not restore its original colour but it will restore its filtration
functions.