Maintenance (expert)
Records
3.6
Maintenance (expert)
Maintenance is necessary at least every 3 years, or when requested by the control system. We recommend
you perform maintenance annually.
Tasks
Notes
Empty the ash box
•
Empty the ash box
•
Check the seals
Check the pressure of the heating system
_________ bar
Check safety devices
•
Visual check of the safety valves
•
Check operational readiness of the safety devices in the fuel path
Chimney
•
Clean the flue tube
•
Flush the chimney's condensate drain
Clean the combustion chamber
•
Clean inside of the secondary combustion chamber
•
Clean primary and secondary combustion chamber
•
Clean tilting grate
•
Clean secondary air openings
•
Clean the ignition tubes
•
Check the firebed button and firebed switch
•
Check refractory lining
Clean flue gas duct
Clean the flue gas recirculation (optional)
•
Check air valve for flue gas recirculation
•
Clean flue gas recirculation ducts
•
Check seal on the maintenance cover
Clean precipitator (optional)
•
Clean the upper section of the precipitator
•
Clean the flushing air opening
•
Clean and inspect the electrode holder
•
Check the alignment of the electrodes
Clean the draught fan
Clean the heat exchanger
•
Clean the heat exchanger
•
Check the heat exchanger tubes
•
Check the seal on the heat exchanger cover
Check the ash box position switch
Check air valve
•
Check air valve for primary and secondary air
•
Perform function test for closing the primary air supply
Check the underpressure sensor
•
Clean silicon hose and connection for the underpressure sensor
•
Calibrate the underpressure sensor
Check de-ashing system