10
www.eta.co.at
Installation
Mounting the trough on the lower part of the drop
chute
Affix a seal to the flange.
Fig. 4-5: Seal
Grease the drive stub of the conveyor screw with
Stauffer grease and connect it with the existing
conveyor screw.
The grease protects the connection from
moisture and thus prevents rust. Therefore the
connection can easily be detached later for necessary
repair, for example.
Fig. 4-6: Conveyor screw
Make sure that the thread is continuous.
Fig. 4-7: Continuous thread
Mount the closed trough on the lower part of the drop
chute.
Fig. 4-8: Closed trough
Attach a seal to the flange. Repeat these steps if
several troughs are installed.
Fig. 4-9: Seal
Mounting the drop shaft for the start of the inter-
mediate screw
The drop chute from the delivery scope of the in-
termediate conveyor screw is always mounted on
the lower part of the drop chute, i.e. always at the start
of the intermediate conveyor screw. See the following
graphic.