When storing, always set the floor nozzle to the carpet position (i.e. with the brush
retracted); thus you will prevent bending of the bristles.
V. MAINTENANCE
Store the vacuum cleaner at a dry place, far enough from heat sources (e.g.
fireplace,
stove, heating element
) and protect it from weather conditions (e.g.
rain, sunshine
).
Treat surface of the appliance with a soft and damp cloth, do not use coarse and
aggressive detergents! Store the appliance properly cleaned at a dry, dust–free place out
of reach of children and incapacitated people.
Floor nozzle, TURBO nozzle, brush
After any vacuuming it is recommended to check visually the brushes or collectors for
possi
ble impurities. If there are some impurities, remove them.
Cleaning the rotary parquet C8 nozzle (Fig. 21)
If long fibres (e.g. hairs) are caught on the rotary brush, remove them so as to ensure
optimal operation of the vacuum cleaner. Using a coin or screwdriver, turn the wheel from
„ “ to „ “ and remove the rotary brush cover. Then remove the brush from the nozzle.
Do not rinse the brush with water! To attach, repeat the above–mentioned procedure in the
opposite sequence order.
Cleaning theTURBO nozzle
If hair or threads are twisted around the mounting of the drive shaft and if they cannot be
removed in the way described above, the impurities have to be removed by dismantling
the nozzles. In the lower part remove the cover. Now you can clean the nozzle using a
suitable tool (eg tweezers). Insert the lid to the nozzle in the opposite direction (you will
hear a snapping sound).
VI. TROUBLESHOOTING
Problem
Cause
Solution
Motor won‘t start
Power supply not connected
Check the cord, plug and the socket
button is not switched on
Push button
Lid cannot be closed -
safety lock activated
Dust filter inserted incorrectly in
the holder / adapter
Check / repair fastening of the front in the
holder / adapter
The remote control
does not work
Batteries are dead (or missing)
Insert charged batteries into the remote control
The vacuum cleaner was not
switched on with the
button
Switch the vacuum cleaner on with the
button
Suction output is
not sufficient
Regulation in MIN position
Set regulation to MAX.
Open suction
Close the hole in the hose handle
Dust filter full
Replace the filter
Clogged micro-filters
Clean or replace the micro-filters
Nozzle, suction hose or tube is
clogged
Remove blocking objects
GB
29 / 48
28