background image

 

E200P Operation Manual 

 

 

Contents 

Preface ........................................................................................................................ 1

 

Chapter 1 Product Introduction ................................................................................ 3

 

1.1 Characteristic ................................................................................................... 3

 

1.2 Operation Panel ............................................................................................... 3

 

1.3 Display ............................................................................................................. 4

 

Chapter 2 Operation Example .................................................................................. 6

 

2.1 Single-Step ...................................................................................................... 6

 

2.1.1 Background ........................................................................................................... 6

 

2.1.2 Analysis ................................................................................................................. 6

 

2.1.3 Procedure .............................................................................................................. 6

 

2.2 Mutil-Step......................................................................................................... 7

 

2.2.1 Background ........................................................................................................... 7

 

2.2.2 Analysis ................................................................................................................. 7

 

2.2.3 Procedure .............................................................................................................. 8

 

Chapter 3 Operation Description ........................................................................... 10

 

3.1 Basic Operation ............................................................................................. 10

 

3.1.1 Start and Stop ...................................................................................................... 10

 

3.1.2 Parameter Setting ............................................................................................... 10

 

3.1.3 Alarm Reset ......................................................................................................... 10

 

3.1.4 Monitor ................................................................................................................ 10

 

3.2 Operation Flow .............................................................................................. 11

 

3.3 Single-Step .................................................................................................... 11

 

3.4 Multi-Step....................................................................................................... 13

 

3.5 Manual ........................................................................................................... 16

 

3.6 Alarm and Monitor ......................................................................................... 17

 

Appendix A    Common fault and troubleshooting ............................................... 18

 

Appendix B    Alarm List .......................................................................................... 19

 

Appendix C  Parameter Description ..................................................................... 21

 

 

Содержание E200P

Страница 1: ...E200P Operation Manual Version V1 02...

Страница 2: ...re 6 2 2 Mutil Step 7 2 2 1 Background 7 2 2 2 Analysis 7 2 2 3 Procedure 8 Chapter 3 Operation Description 10 3 1 Basic Operation 10 3 1 1 Start and Stop 10 3 1 2 Parameter Setting 10 3 1 3 Alarm Res...

Страница 3: ...he system Operator use the machine to do the programming work set the programming constant parameters Attention Copy right is preserved by ESTUN Do not add or delete part or all of the manual content...

Страница 4: ...ully and adhere them strictly Risk of injury If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals If you do not adhere t...

Страница 5: ...tion to improve the positioning precision and reduce screw clearance The main action of the machine can be configured such as fast closing pressing decompression opening Backgauge can automatic homing...

Страница 6: ...user input symbol or start diagnosis Numeric key when setting parameter input value Decimal point key when set up parameter input decimal point Manual movement key in case of manual adjustment make a...

Страница 7: ...5 Current Position here shows the relative position of the X axis and Y axis Parameter editing area here shows the editable parameters Interpretation and Unit here shows interpretation and unit of pa...

Страница 8: ...or the backgauge retract waiting is 2 00s Time for the block holds the pressure is3 00s Workpiece is 10 2 1 2 Analysis Parameter Setting XP 80 00mm YP 100 00mm DX 5 00mm HT 3 00s DLY 2 00s PP 10 Other...

Страница 9: ...hird bending 300mm 2 2 2 Analysis According to the process condition of workpiece and tool analysis data are as follows The first bending Position of the backgauge is 50 00mm Depth of bending is 85 00...

Страница 10: ...ault page Step 2 Press to enter PROGRAMS page Step 3 Press or arrow key to select 2program and then press to enter the NO 2 PROGRAM page Step 4 According to the analysis press the arrow keys and numbe...

Страница 11: ...00 mm DX 5 00 mm OPEN DIST 0 00 mm Repeat Times 1 TIMES Figure 2 3 Step configuration Step 6 According to Step 5 modify the parameters on the 2 3ST and 3 3ST pages Step 7 Press back to PROGRAM page S...

Страница 12: ...meter Setting When editing the parameter press to select the parameter you want to modify input the value and press to finish When editing the parameter please accord to the tip on the page to edit If...

Страница 13: ...3 Single Step In the actual processing operator user pedal switch to control the bending process Because of the SINGLE page has simple and direct parameter it more suitable for the bending operation j...

Страница 14: ...9999 999 mm inch Program position of X axle YP 0 00 0 9999 999 mm inch Program position of Y axle DX 0 00 0 9999 999 mm inch Retract distance of X axle HT 0 00 0 99 99 s The interval time from LDP sig...

Страница 15: ...umber is used for storing Mutil Step programming in order to work again E200P CNC device provide 40 Program Number to user Press to select the target Program Number and press to enter and then the edi...

Страница 16: ...ain work piece DLY 0 00 0 99 99 s In case of single step delay time for X axle retracting HT 0 0 0 99 99 s The interval time from LDP signal to decompression process Step 4 After finishing the setting...

Страница 17: ...999 mm inch Program position of Y axis DX 0 00 0 9999 999 mm inch Retract distance of X axle OPEN DIST 0 00 0 999 999 mm inch After bending the distance of the Y axis opening Repeat Times 1 1 99 The...

Страница 18: ...ld the motor control this axis runs to the increment count direction slowly Move the cursor and stay on the axis you want to adjust press and hold the motor control this axis runs to the decrement cou...

Страница 19: ...19 20 01 02 03 04 05 06 07 08 09 10 OUTPUT 11 12 13 14 15 16 17 18 19 20 IO MONITOR INPUTS INPUT OUTPUTS OUTPUT ST PS PD PU MD SI MR NC Y1 Y2 Y3 Y4 Y5 EH ER Figure 3 7 The IO MONITOR page On the CONST...

Страница 20: ...oes not move Check whether mechanical part has been locked or slider returns to upper dead center Check whether the motor wiring is connected well When the device is in multi step programming the prog...

Страница 21: ...t position when the Y axis is in positioning A 12 Finished work The count reaches the preset value need to manually clear alarm A 13 X Un teachIn You shall teach the X axis first A 14 Y Un teachIn You...

Страница 22: ...SYNC04 The servo has occurred the insufficient voltage alarm A 54 SYNC05 The servo has occurred the RAM chip abnormal alarm A 55 SYNC06 The servo has occurred the AD sampling error alarm AX 01 AX 59 A...

Страница 23: ...orrect value to represent the backgauge current position Y tea in 10 00 0 9999 999 mm inch When the teaching of Y axis is enabling the operator assigns to the Y axis of a correct value to represent th...

Страница 24: ...steps in this program PP 0 99999 The number of processing workpiece in this program CP 0 99999 PP 0 this value is the current work piece PP 0 this value is the remain work piece DLY 0 99 99 s In case...

Страница 25: ......