Appendix C Parameter Description
Parameter
Default
Range
Unit
Description
CONST
mm/inch
0
0~1
-
0: mm
1: inch
中文
/English
0
0~1
-
0:
中文
1: English
Release Delay
0.50
s
The delay time for the slide
releasing the pressure after
bending.
Version
-
-
-
The current software version
number.
TchIn PARA
X-tea. in
10.00
0~9999.999
mm/inch
When the teaching of X-axis
is enabling, the operator
assigns to the X-axis of a
correct value, to represent
the backgauge current
position.
Y-tea. in
10.00
0~9999.999
mm/inch
When the teaching of Y-axis
is enabling, the operator
assigns to the Y-axis of a
correct value, to represent
the slider current position.
CONFIG PARA.
YV5->NCRDY
0
0, 1
-
0: Disable, the function of
YV output is normal.
1: Enable, the function of
YV output is changed to
NCRDY output.
Jog Mode
0
0, 1
-
0: Semi.
1: Jog
SINGLE
XP
0~9999.999
mm/inch
Program position of X axle.
YP
0~9999.999
mm/inch
Program position of Y axle.
DX
0~9999.999
mm/inch
Retract distance of X axle.
HT
0~99.99
s
The interval time from
LDP
signal to decompression
process.