1 .  This is an electric machine user manual, in which operation, maintenance and safety information are 

specified . Please read and file it carefully .

2 .  After unpacking, please check to ensure your machine has not been damaged during shipping . 

Please notify your service representative or qualified technician regarding all questions or concerns 

before installing . Please note that the machine package material, including plastic bag and Styrofoam, 

can be dangerous and should be kept out of reach of children .

3 .  There is an identification label on the front of unit . Before operating, please check to ensure the power 

source corresponds to the rating shown on the identification label . The manufacturer is not responsible 

for issues resulting from improper installation and usage .

4 .  Please use separate power source which corresponds to the unit’s power rating .
5 .  Please use No Fuse Breaker (NFB) that conforms to the safety regulation separately .  Do NOT use a 

socket . The NFB should have a minimum contact space of 3 mm and provide electrical spike and drain 

protection . The ampere must be sufficient for providing the required electric current to this machine .

6 .  Be sure to use a grounded power source to prevent electric shock and ensure the safety of this machine 

and relative personnel .

7 .  The machine must be used in accordance with its original design . Additional use is inappropriate and 

dangerous . Injury or loss caused by wrong use or operation mistake will be beyond our responsibility .

8 .  The temperature of the steam wand, hot water wand and brewing group is very high . Use caution while 

operating .

9 .  Please follow maintenance and cleaning instructions specified in this manual to ensure the best operation 

efficiency of machine .

10 .  If the machine breaks down or functions abnormally, please turn off machine and its power source and 

notify professional maintenance personnel to fix; Electrical components can be dangerous . We are not 

responsible for the behavior conducted by unauthorized service personnel .

11 .  Please use filtered and softened water . If using groundwater or tap water for brewing coffee, please 

soften it first . Unsoftened water will decompose dissolvable minerals and turn to limescale after boiling . 

The limescale will reduce the machine’s thermal efficiency and machine’s lifetime .

12 .  Machine refills water automatically . The light on touch panel will flash as self-detection if water flow into 

machine exceeds two minutes (see Trouble Shooting Section), and power will be cut off automatically to 

protect the system . To resume normal functions, turn off the machine for 2-3 seconds and turn on the 

machine again .

13 .  The heating element will not operate when water in the machine is less than the minimum required level . 

When starting the machine without any water in the tank, heating will be delayed for about 60 seconds .

14 .  Before the use of machine, you must confirm there isn’t any frozen water inside the boiler . Even though 

the machine hasn’t been installed, the temperature for water must be kept over the freezing point . The 

damage caused by frozen water inside the tube or boiler won’t be covered by the manufacturer .

15 .  Machine is shipped from factory with water drained from boiler and exchanger . Please ensure the 

machine to be drained completely before it is removed and put away for storage . If water gets frozen 

inside the pipes and boiler of the machine, it can damage machine . For install and removal of the machine, 

please contact a qualified service person .

GENERAL

Содержание 236ECEM1

Страница 1: ...04 2022 236ECEM1 1 Group 236ECEM3 3 Group 236ECEM2 2 Group ESPRESSO MACHINES USER MANUAL...

Страница 2: ...s 3 Installation 3 Setup 3 Operation 5 Cleaning Maintenance 6 Parts Diagram 8 Wiring Diagram 236ECEM1 9 Wiring Diagram 236ECEM2 10 Wiring Diagram 236ECEM3 11 Warranty 12 INDEX NOTE Save these instruct...

Страница 3: ...ctions specified in this manual to ensure the best operation efficiency of machine 10 If the machine breaks down or functions abnormally please turn off machine and its power source and notify profess...

Страница 4: ...re A cold water connection is required for this unit to function properly Contact a qualified technician to ensure that your electrical and water setup are correct to the specifications of the machine...

Страница 5: ...eft OUTPUT VOLUME AND FREQUENCY SETUP 1 To program turn the output volume setup switch ON Fig 1 2 The output LEDs Fig 2 should be lit with the 5th button flashing indicating the machine is in setup mo...

Страница 6: ...ing from the right output system to the left 2 The default is 10 cleaning cycles 3 If you want to stop before the completion of all 10 cleaning cycles press button 3 4 Flush the group after flushing t...

Страница 7: ...eat gasket and remove residual coffee grounds from the inside 4 Flush the steam outlet in REVERSE daily before shutting off the machine 5 Remove the copper plate and filter element from the water outl...

Страница 8: ...e tube Drain is for use with liquids only DO NOT put any solids coffee grounds etc down the drain To extend your boiler s serviceable life when the machine is expected to sit idle for a period of one...

Страница 9: ...b 2 Espresso Brewing Unit Control Panel 3 Steam Knob 4 Brewing Group 5 Steam Tube 6 Main Power Switch 7 Drain Tray Description 8 Foot 9 Sight Glass Boiler Water Level Check Window 10 Espresso Filter H...

Страница 10: ...switch Motor pump connector connector Water level probe Operation panel group1 Ground Flowmeter group1 Dosing setting Ground Water inflow solenoid valve Group1 solenoid valve Temperature Protector G...

Страница 11: ...wer switch Motor pump connector connector group1 Ground Flowmeter group1 Dosing setting Flowmeter group2 group2 Operation panel Water level probe Ground Water inflow solenoid valve Group1 solenoid val...

Страница 12: ...onnector connector group1 Ground Flowmeter group1 Dosing setting Flowmeter group2 Flowmeter group3 group2 group3 Operation panel Water level probe Water inflow solenoid valve Group1 solenoid valve Gro...

Страница 13: ...ear and tear misuse abuse vandalism or Act of God Total Dissolved Solids Minimum 50 PPM Maximum 125 PPM Total Hardness Minimum 3 GPG Maximum 5 GPG pH Minimum 6 5 Maximum 7 5 Free Chlorine Maximum 0 5...

Страница 14: ...urchase is required to obtain warranty coverage This warranty is only valid to the original purchaser and only to equipment installed in the contiguous United States The warranty is not transferable a...

Страница 15: ......

Отзывы: