11
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-NL240/NL240 Capacity 240 Gallons (908 Liters)
Model WF-L400/L400 Capacity 400 Gallons (1514 Liters
)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 63°F (17.2°C).
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Model WF-NL240: Change cartridge at least every 6 months.
Use replacement cartridge NL240, part #4396508.
2006 suggested retail price of $32.99 U.S.A./$44.95 Canada.
Prices are subject to change without notice.
Model WF-L400: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L400, part
#4396508. 2006 suggested retail price of $32.99 U.S.A./
$44.95 Canada. Prices are subject to change without notice.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■
Refer to the front cover or “Assistance or Service” section for
the Manufacturer’s name, address and telephone number.
■
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine Taste and Odor,
Particulate Class II*; and against ANSI/NSF Standard 53 for
the reduction of Lead.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class II
*
≥
50%
≥
85%
1.9 mg/L
833,333/mL
2.0 mg/L ± 10%
At least 10,000
particles/mL
0.05 mg/L
100,000/mL**
0.05 mg/L
40,667/mL
97.4%
88.0%
97.4%
95.1%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01 mg/L
0.01 mg/L
0.15 mg/L***
0.15 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.003 mg/L
0.001 mg/L
0.001 mg/L
99.3%
97.9%
99.3%
99.0%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi.
*
**
***
Class II particle size: >1 to <5
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
Содержание TS25CGXTD
Страница 13: ...13 Notes...