background image

 

 

10 

EST-64 GSM Remote Control Device 

 

EST-64– USER MANUAL – Rev.2.4 – Technical Support:

 1-800-640-4283 

  

COPYRIGHT ©2008 Estate Swing 

 

 

#PWD123456#COA=00005

 

 

 

 

 

 

This input  can  be  programmed  to  behave  differently,  it  can  count  the  input  active  high 

pulses,  generate  an  alarm  message  or  activate  relay.  To  program  the  input,  you  can 

send the following commands by SMS message to the unit. 

 

Text Command: 

 

#CTC=

 

F stands for input function 

5

 

 

Function Descriptions 

 

Function 

1

:  

 

Function as counter 

 

Sends a counter alert message once alarm counter reaches the alert value 

 

Function 

2

 

Function as counter 

 

Activate the output relay 2 to stay on 

 

Sends a counter alert message once alarm counter reaches the alert value 

Function 

3

 

Function as counter 

 

Activate the output relay 2 to stay on 

 

Sends an alert message once triggered 

 

Sends a counter alert message once alarm counter reaches the alert value 

 

Function 

4

 

Function as counter 

 

Activate the output relay 2 for 1 second 

 

Sends a counter alert message once alarm counter reaches the alert value 

 

Function 

5

 

Sends an alert message once triggered  

 

5.1.6  SETTING THE FEATURE FOR INPUT

 

Содержание EST-64

Страница 1: ...E ES ST T 6 64 4 G G GS S SM M M R R Re e em m mo o ot t te e e C C Co o on n nt t tr r ro o ol l l D D De e ev v vi i ic c ce e e User Manual E E ES S ST T TA A AT T TE E E S S SW W WI I IN N NG G G...

Страница 2: ...GSM Remote Control Device EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing Electronic KIT to convert your gate into a GSM gate EST 64 GSM Remote Control Device...

Страница 3: ...Safe nobody can clone your phone as easily as they can do with a standard remote control 2 Flexible you can add or remove anybody number in a minute with an SMS 3 Cheap you don t need to buy a remote...

Страница 4: ...before inserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so If...

Страница 5: ...indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position To add a number the syntax of the command is the following PWD123456 WHL0...

Страница 6: ...33444 you need to send the following SMS PWD123456 CAP333444 CAP333444 You will receive a confirmation with CAP OK if you wrote correctly GOT Gate pulse time This command is useful in case you need to...

Страница 7: ...gh Going Pulses One of the most important functions is to receive alarms In order to do this properly you must program the administrator numbers turn on the function of the input and tell the EST 64 w...

Страница 8: ...N XXXXXXXX XXXXXXXX stands for 8 digits value ON 1 or OFF 0 for the 8 administrators For example if you assume only administrators 1 2 3 and 4 are to receive text alerts you would send the following S...

Страница 9: ...N 1 or OFF 0 value To turn on the input the syntax of the command is the following PWD123456 CTR 1 An alert message will be sent when the increment of alarm counter reaches the alert value Default 500...

Страница 10: ...Function as counter Sends a counter alert message once alarm counter reaches the alert value Function 2 Function as counter Activate the output relay 2 to stay on Sends a counter alert message once a...

Страница 11: ...t Text Command COU The syntax of the command is the following PWD123456 COU You will receive the total increment value from the unit by SMS To read the sub increment counter value you can send the fol...

Страница 12: ...m of 65 535 seconds Text Command RLY N XXXXX N stands for number 1 or 2 of Output XXXXX stands for 5 digits value The number of seconds For example assume you want to turn on the output relay number 2...

Страница 13: ...y when the relay has turned on off This is to notify the administrators when someone outside the list activates the relays The output relays can be programmed to operate with special feature After pro...

Страница 14: ...efer to 5 3 2 and 5 3 3 To program the output relays to operate with function 2 the syntax of the command is the following PWD123456 FTRY 2 The output relay can be programmed to operate at a programma...

Страница 15: ...n for each relay To set the time you can send the following SMS command to the unit The time is entered in 24 Hour format Text Command TSET SS MM HH SS stands for 2 digits value Seconds MM stands for...

Страница 16: ...d would be 33VDC To set the output relay 2 to use dry contact Default when activated please adjust the jumper according to the below diagram To reset the unit you can send the following SMS command to...

Страница 17: ...ough properly but the gate will not open by calling the receiver Check your wiring to your gate opener If that is fine then try reprogramming with a 1 in front of all the numbers Some networks add the...

Отзывы: